Customer:
James from Monterey, TN
Parts Used:
WB08T10026
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
broken light socket
The only tool needed was a nutdriver to remove the lamp socket. I needed my head mounted light to see what I was doing, and everything went smoothly from there. Simple job.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Albuquerque, NM
Parts Used:
WB02T10017
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Convection fan came loose from shaft
Convection fan came loose from the shaft with a lout rattle and grinding as the fan spun down. Had to remove four metal screws to remove the fan cover. Initially tried to just put the nut back on to hold the fan. However, I could not get the nut to start, so I assumed that threads were stripped on the nut or the shaft. Ordered the replacement nut, hoping that it was the nut that was the problem. However, I had the same problem with the new nut. I could see no damage on the shaft. It finally occurred to me that the nut and shaft had left-hand threads (counter-clockwise to tighten). At that point, it was extremely easy to put the nut back on and tighten it. I did not try using the old nut, since I had already received the new one, but I'm certain that if I had come to that realization earlier, I could have saved time and money. So, if you have the same problem, try putting the nut on "backwards."
Was this instruction helpful to you?
Thank you for voting!