- Customer:
- Barbara from Bethesda, MD
- Parts Used:
- WB04T10050
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
gasket on door was brittle
I feel like Macho Mom. I called in the repair guy since I was afraid of dealing with the gas. HE repaired one item but could tell I was comfortable fixing things and pointed out that the gasket was brittle and would cause major problems if not replaced. Took longer to order the part than do the repair, don't know what I was afraid of!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from Delray Beach, FL
- Parts Used:
- WB24T10119
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
burner worked on high only
Followed directions from Rodney of Erath La. Directions were perfect and helped me to decide to under take this job. Job took a little longer spending some time to clean the glass top on both sides and around the counter top where it mounts. The actual repair time was quick and easy thanks to Rodney. Price of the part was reasonable and delivery got here quick. Will deal with parts select again! Carl from Florida
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Acme, WA
- Parts Used:
- WB23T10015
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
oven temp. was not what setting called for
turned oven off, pulled oven out from wall, removed back of oven, unscrewed sensor from oven replaced with new sensor, put back on, turned power to oven on, tried oven at 425, my temp. gage and the oven temp matched. a very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Albuquerque, NM
- Parts Used:
- WB02T10017
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Convection fan came loose from shaft
Convection fan came loose from the shaft with a lout rattle and grinding as the fan spun down. Had to remove four metal screws to remove the fan cover. Initially tried to just put the nut back on to hold the fan. However, I could not get the nut to start, so I assumed that threads were stripped on the nut or the shaft. Ordered the replacement nut, hoping that it was the nut that was the problem. However, I had the same problem with the new nut. I could see no damage on the shaft. It finally occurred to me that the nut and shaft had left-hand threads (counter-clockwise to tighten). At that point, it was extremely easy to put the nut back on and tighten it. I did not try using the old nut, since I had already received the new one, but I'm certain that if I had come to that realization earlier, I could have saved time and money. So, if you have the same problem, try putting the nut on "backwards."
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from Plymouth, NH
- Parts Used:
- WB24T10134
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
intermittent between low & high elements
remove knobs and plastic nuts behind them, remove the six hex head screws holding switch plate, Remove two screws holding problem switch to plate. Swap wires one for one and reverse the process to complete repair. PS don't forget to turn off the range at the breaker panel.
Was this instruction helpful to you?
Thank you for voting!