JCSP42SN2SS General Electric Range - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- TERRY from RICHMOND, VA
- Parts Used:
- WB02X33180
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
rear drawer supports broke
Directtions were by diagram only, no written instructions. Drawing was small and difficult to follow but the repair itself was easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ruth Ann from New Columbia, PA
- Parts Used:
- WB30T10133
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The middle of the element quit working.
Took the old burner out, tranferred the wires from old to new. Installed the new burner. Works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from Plymouth, NH
- Parts Used:
- WB24T10134
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
intermittent between low & high elements
remove knobs and plastic nuts behind them, remove the six hex head screws holding switch plate, Remove two screws holding problem switch to plate. Swap wires one for one and reverse the process to complete repair. PS don't forget to turn off the range at the breaker panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- brendan from lebanon, NH
- Parts Used:
- WB17T10011
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set, Wrench set
one leg of the terminal block was loose and overheated under load.the terminal block melted and could have caused a fire.
I took a picture of the setup and damage . I then disconnected the burnt wires and replaced the wires . Then I installed the new terminal block and connected the wires to the proper positions. The reason for the failure was that the delivery people didn't tighten the cord when they installed the stove . I would check the connections periodically as to avoid another situation like this .
Was this instruction helpful to you?