Customer:
Edwin from Quincy, CA
Parts Used:
WR55X10025
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Zachary from Decatur, GA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Fridge was freezing food near the back, adjusting internal temp not fixing the problem
Unplugged the refrigerator first....then on the inside of the fridge, I popped the temp sensor cover off (upper LH side) and exposed the old sensor. I snipped off the old sensor about 3" down from the end and connected the new sensor (which I trimmed down to about 3" long) with some heat shrink wire nuts/connectors. Let the fridge run for a day or so and confirmed the problem was solved! Oh yeah, there was no way to tell the 2 wires apart (power vs. ground) on the sensor. However there was a manufacturer's stamp on the wires. So note the orientation of the text and mark one of the wires with a sharpie on both the old and new sensor before trimming. This will give you a reference for which wires to connect when adding the new sensor to the old wires.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Plainfield, NH
Parts Used:
WH23X10028
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Washer pump faile
Removed old pump and replaced. Did not want to wait 2-3 weeks for a repair person
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Warrenton, VA
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Refridgerator not cooling, freezer frosting over
First, I had to remove the freezer drawer front. This is 8 large phillips head screws. then remove the plastic cover over the drawer slides. to do this, remove the white center screw from the slide near where it attaches to the drawer front. then the plastic cover will slide off pushing to the rear of the slide. take off the slides from the freezer walls by removing the phillips screws and pulling them towards you. They have tabs/slots in the rear. remove the center tray support and support bars, too. the icemaker has to come out, that is just 2 phillips screws but you also have to disconnect the electrical connector. just squeeze the locking wings and rock/pull. a screw in the top center of the back panel comes out. Lift and pull the back panel out. The evaporator coil appears. The thermocouple is attached to the coil in the upper right. Cut that one's wires and take it out. Just cut back about an inch from the back of the thermocouple, there is not much slack. Seperate and strip the wires back about 3/8 inch. Do the same for the new thermocouple. I twisted the wires together and used a solder sleeve to join the wires. The sleeve is just a little plastic tube that has a ring of solder in it that melts with heat gun heat. You can join the wires using butt connectors or whatever method appeals to you. I just wound the extra wire and put a cable tie around it, there is plenty of hiding space in that area. Make sure the new thermocouple is contacting the coil firmly.At this point, for a test, I left everything apart, propped the drawer against the opening and plugged the fridge in. Note that the evaporator fan will not start spinning immediately! It will just sit there making little bumps like it wants to go. The temp in the coil has to get settled before the electronics in the refridge will tell the fan to spin. It takes maybe 20 minutes. Reassemble. Fridge and freezer work great. It does take several hours for all to get cold again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nick from Burnt Cabins, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Fridge/Freezer getting too warm
What an awesome site! After putting in my model number and finding the problem I was having, I simply picked the 2 parts that were most likely to solve the problem. I bought a defrost thermostat, and defrost heater. To a high certainty, they would solve my problem. They didn't however! I ended up having to buy a temperature sensor on another order a few weeks later when the problem resurfaced! My own fault. I should have bought it the first time. As others have written: the longest part of the job is defrosting the ice from the coil. One thing I did that I didn't see suggested: plug the drain hole below the coil. I put a couple towels in the bottom of the freezer and ran the hair dryer. Didn't take long. I read that the amount of water created will overflow the pan under the refrigerator, so I plugged the drain hole. Once you clean that mess up, the repair is pretty straight forward. Great site. Even through I had to make two separate purchases, I still saved a lot of money. Thanks!
Was this instruction helpful to you?
Thank you for voting!
Customer:
philip from cocoa, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer would not defrost
There were only 3parts listed to check omed out the defrost heater and thermostat ....thermistor checked bad ordered replacement took less than 2 minutes to replace after I defrosted it again runs fine
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Simpsonville, SC
Parts Used:
WR23X37285
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
light switch quit working
removed the inside fridge electrical panel and swapped switches
Was this instruction helpful to you?
Thank you for voting!
Customer:
ANTHONY from NEW EGYPT, NJ
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
sticky switch
easy pry out, disconnect wiring, connect on new switch and press in switch.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Durham, CA
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
compressor running and hot, refer and fridge room temp.
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOSE from NEW YORK, NY
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fan and compressor wont start
Googled the model number of refrigerator with symptoms of "refrigerator wont run". Parts select web site appeared on my screen, opened Parts Select website, Partselect said probable cause of my frige symptom was that the run capacitor usually burns out 51% of the time. They were correct with the diagnosis 100%. I ordered the run capacitor for $23.00, installed it in 10 minutes, refrigerator runs good as new. Thank you for saving me cost of service call. I probably saved $200 or more. I will use Partselect again with my next problem. THANK YOU,