PHB920SJ7SS General Electric Range - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Shakopee, MN
- Parts Used:
- WB02X33180
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Stove drawer rear guides broken
Installed new guides with a nut driver without any problems.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Newark, DE
- Parts Used:
- WB02X33180
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Range lower drawer would not stay on track.
Easy to install replacement parts using the screws provided.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mario from Deer Park, WA
- Parts Used:
- WB02X33180
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Broken drawer support
Followed the example picture on the part bag. Anyone could do this, incredibly easy. Took about 4 minutes to install both sides.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Stuart, VA
- Parts Used:
- WB02X33180
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Plastic slide for storage drawer broken.
Took part out of package, looked at instructions and followed them. Required a screwdriver to screw part on to the drawer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- brendan from lebanon, NH
- Parts Used:
- WB17T10011
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set, Wrench set
one leg of the terminal block was loose and overheated under load.the terminal block melted and could have caused a fire.
I took a picture of the setup and damage . I then disconnected the burnt wires and replaced the wires . Then I installed the new terminal block and connected the wires to the proper positions. The reason for the failure was that the delivery people didn't tighten the cord when they installed the stove . I would check the connections periodically as to avoid another situation like this .
Was this instruction helpful to you?
Thank you for voting!