- Customer:
- David C from Huntington Beach, CA
- Parts Used:
- 316490001
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Temperature not correct.
Pull out stove. Unplug power. Remove four screws on each corner and loosen one screw in the middle. Remove back panel. Locate and unplug sensor connector. Remove one screw from sensor plate. Turn the sensor 45 degrees and pull sensor out from the rear. Connector received had the incorrect plug and terminals so it was necessaary to splice the connector from the one removed to the one received. Cut and splice wires as necessary. Install sensor, install back panel, plug in electrical power, push stove back into position. I used a temperature gauge to check temperature after stove was in position. In my case the temperature had to be adjusted which is a keyboard function on this unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from Mansfield, MA
- Parts Used:
- 316490001
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
oven would turn on and stay on regardless of set point
Pulled oven from counter space unplugged unit unscrewed 9 - 1/4" tech screws then one more 1/4" tech screw that holds the sensor.Inserted the new element cut the two wire because it was a different connection stripped the wires and did the same to the old element but used the old plug.Connected the plug,plugged the over back in slid the unit back and turned out on for a test.All is well,thank you!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAONNE from GAFILED, NJ
- Parts Used:
- 316490000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
oven took too long to heat up
un bolted the 6 nut driver heads found probe wire un pluged it 1/4 turn from lock it was in and pull out replace slide in new probe 1/4 turn to lock it in place replace nut driver self tappers and test simple!!
Was this instruction helpful to you?