YKCMS145JBL0 KitchenAid Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Scott from Mickleton, NJ
- Parts Used:
- 4392027
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would not cook
All the electrics worked on Amana microwave EXCEPT for the cooking function. Inspected the control board and found the upper switch on the door interlock was burnt. Installed new switch in minutes and everything now works fine. Unfortunately, had to purchase expensive two switch "kit" although only one switch was kaput. PartsSelect mailing was SUPER fast. Thanks for looking, Scott
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Studio City, CA
- Parts Used:
- WPW10267856
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
My glass tray broke in the microwave.
I called to make sure I was replacing the correct part. I paid over the phone and it came the next day. Very very easy process.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ramo from Sylvan Grove, KS
- Parts Used:
- WP8183507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Stopped working completely
My wife was pushing a few buttons with her knuckle (hands were full)and the microwave just turned off. Just like we had blown a breaker. First I unpluged it. Then I removed the phillips screws of the front panel, and found and removed the ceramic fuse. 3 days later I received the new fuse in the mail, and put it in. I plugged the microwave back in and it works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lewis from Loveland, CO
- Parts Used:
- 4392027
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
motor would start by itself when door closed
remove 4 screws from top, front louvered panel snaps out. remove 1 screw from top of keypad, keypad pivot's forward and can be removed. There is a white mounting bracket inside left. Remove two screws, one top and one bottom, bracket lifts up and out. 3 sets wires are attached, mark them with masking tape, top, center, bottom and pull out plugs. They can only attach one way. Using a very small screw tip, lift plastic latch from switch, it rotates out and is removed from the pivot pin. reassemble in reverse order after switches are replaced
Was this instruction helpful to you?
Thank you for voting!