Models > JVM1190SYC02 > Instructions

JVM1190SYC02 General Electric Microwave - Instructions

Jump to:

All Instructions for the JVM1190SYC02
31 - 45 of 97
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Lois from El Segundo, CA
Parts Used:
WB24X829
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave would turn on when door opened
Unscrewed numerous screws holding the "body/shell" to the microwave. Removed body. I then unplugged top door switch, replaced it with new one, and "tested" the new one. I fixed our $400 convection micro with an $18 switch. NICE!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
RICHARD from Santa Rosa, CA
Parts Used:
WB39X75
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Bottom Of Oven Cracked
Removed broken bottom tray no tools needed slid new tray in, rather a tight fit because of the gaskets around the edges. The door now must be more firmly closed. Works fine. . Wife happy. . . . . . .
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Austin, TX
Parts Used:
WB36X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Inside Bulb went out.
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from POWHATAN, VA
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ernest from RIVERSIDE, CA
Parts Used:
WB24X830
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Enfield, CT
Parts Used:
WB27X10240
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
chattering noise/ burning smell
Removed control panel disconnected old capacitor installed new and returned the leads back on to the new. replaced control cover and tested
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Fort Myers, FL
Parts Used:
WB39X75
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ceramic base in microwave split
Pulled old base up easily with screwdriver. Slipped new base in very easily. Perfect fit.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ernest from Riverview, MI
Parts Used:
WB27X10585
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
oven made a loud buzzing & would not heat
completly removed outer cabinet,discharged capicator,removed some internal parts so I could get at the magnetron,
.removed replaced magnetron,reinstalled inner parts& cabinet .tested microwave viola
everything worked again.
Thanks, PartsSelect
Ernie
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from Leesburg, FL
Parts Used:
WB36X10003
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
NO light
.Thank You Dan
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from SAN JOSE, CA
Parts Used:
WB27X7
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
CERAMIC FUSE BLEW WHILE HEATING VEGETABLES
I found an exploded view diagram of of my microwave model which was very helpful. You need only remove outside metal skin by removing 4 screws on either side and 4 more on the back. Remove 4 plastic hole plugs from the top mounting inserts. Gently pull sides out and lift up and back to remove outer skin. The fuse is located on the back right corner behind the control panel. You access from the side. The fuse is under the spreader bar. Lift fuse up gently to remove.

P.S. It was the MSP Capaciter and or the interlock switch, snap apart 21A (19) failure that actually caused the ceramic fuse to blow.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Beverly from PARSIPPANY, NJ
Parts Used:
WB4X174
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Rack in freezer keep falling down.
The spacer just snapped onto the rack giving it a little more width to hold the shelf on the guides. Not the best fit but hopefully will do the trick long term. I thought it would have been a bigger part.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allen from YONKERS, NY
Parts Used:
WB6X60
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
While removing for cleaning, grease filter fell behind stove. Could not be retrieved.
Simply slid new part into track holder by hand.)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Judith from LOCKPORT, IL
Parts Used:
WB6X60
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Dirty grease filters
Slide out the old ones then slide in the new ones. A 30 second job.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from SUN PRAIRIE, WI
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
When door opened, microwave would turn on
Removed the outer cover to access the door switches. Turns out there were three switches, but I determined that only two were bad. When the small colored tab on the switch is pushed in it should make a clicking sound. The two bad switches had no resistance and did not make any noise when pressed. Removing the switch is relatively easy, you simply pull it away from a couple small tabs holding them in place. After reconnecting the wire leads, insert back into the holding tabs and install the cover.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DeWitt from Boulder, CO
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The microwave turntable rotates when the door is open.
This is sometimes described in other repair notes as "microwave 'runs' when door is open."
With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open.
Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower.
There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon.
Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JVM1190SYC02