Models > PVM9215DK1BB > Instructions

PVM9215DK1BB General Electric Microwave - Instructions

Jump to:

All Instructions for the PVM9215DK1BB
76 - 90 of 115
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Hugh from Slippery Rock, PA
Parts Used:
WB36X10071
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
glass light lens were broken
All one has to do is use a screw driver to remove the screws, one per lens.
Then lower the lens bracket, bend the 4 tabs holding the
lens, remove and replace the lens and screw the brackets back in place.

Less than 10 minuits.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mack from Jacksonville, FL
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
No heat.
Replaced the fuse. Result; did not fix the problem.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lucinda from Burke, VA
Parts Used:
WB49X10063
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
dropped the glass cooking tray while cleaning
after a couple of misfires, got the correct size tray, and replaced it in the oven.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edwin from New York, NY
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
No heat
Replace the fuses
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Shawnee, OK
Parts Used:
WB24X829
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
oven wouldn't heat
remove cover-unplug wires from secondary switch-remove switch-snap in new switch-plug in wires-replace cover-works great. very easy to do.
3 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Navarre, FL
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave came on when door open
Turn off main power bracker. Removed fan vent, removed control panel, disconnect leads to the three monitor switches. Replaced the secondary switch (top). Reversed procedures.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Julie from Elm Grove, WI
Parts Used:
WB24X829
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave fan would run when opening the door. Evenutally the mircowave would not run, but the electrical panel was still working
Opened the microwave oven door, unscrewed two screws which held the control panel on, then I removed two of the door switches (each had two screws), and then used the continuity tester to see which one was not operating. It turned out to be the secondary door switch, replaced it and to my amazement, the microwave worked. I have never repaired an appliance before but I didn't want to replace our over-the-stove built in microwave. It was the best day ever when it was working again! The hardest part was getting myself to try the repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clarence from Rocky Ridge, OH
Parts Used:
WB24X829
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
When opening door the microwave would turn on.
Watched How to repair a Microwave that turns on when the door is opened Video on the web. From this took a shot at the switch was the problem. When I removed the switch it was defective. The small button was in and when you turned the switch upside down the button would drop back into position. Ordered a switch for $25.oo , installed it and the microwave is working fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Mountain View, AR
Parts Used:
WB24X829
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave worked but oven fan came on when door was opened - should onlly come on when oven is operating.
Removed the microwave with the buit in housing from the cabinet. Removed microwave from built in housing. Removed outer cabinet giving access to remove control panel and smart board where switches are located. Removed control panel to get to smartboard. Removed smart board after disconnecting a few wires to allow easy removal. Individually removed and then tested each switch using multimeter. Found seondary Door Switch (bottom of smart board) operation to be intermittent (switch trip button extremely loose and rattle inside this particular switch) Ordered replacement part which came very quickly on standard shipping order. Put new switch on smart board and remounted, reinstalled control panel and reconnected various wire connectors previously disconnected. Then plugged in oven and tested for opertation - didn't work at all! But, after bleeding off capacior charge by removing connectors and discharging capacitor to ground, then reassembling control board and smart board into oven, then trying agian, it has worked perfectly ever since. Do not understand why capacitor disconnect/discharge was required but suspect this reset the control electronics. Easy fix and hope to get another 12 years out of this appliance which is used multiple times every day. Also have two other identical micorwave ovens, one is 20 years old, but these get used relatively infrequently.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Neal from White House, TN
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Motor and fan turned on when door was opened.
Loosen the two long anchor bolts that screw into the top of the microwave cabinet. These are usually in a shelf or cabinet directly above the microwave. Tilt the microwave forward enough to remove the 2 Phillips head screws from the top of the microwave cabinet. They are near the front. When these two screws are out, remove the fan vent. Once the fan vent is off, remove one screw that holds the control pad in place. Let it hang down. Just to the left of the control pad, you will see wires leading to three switches that close when the door is closed. Use a torx driver to remove the two screws that hold the switch bracket in place. With the bracket out, unplug the wire harnesses. On the opposite side of the wiring connected, a tab holds each switch in place. Lift the tab and slide the switches out. Usually, the bad switch will be identified by a loose or broken spring. Test them by pressing down on the switch. If you notice the bad switch spring, this is usually the bad one. When you have the new one, simply push it back into the appropriate slot and be sure that the holding tab snaps back in place. Plug the wires back in and re-attach the bracket. Put the control pad back on, then the fan vent. When down with those, push on the bottom of the microwave to lift it back into place and tighten the two anchor bolts in the top.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from Umatilla, FL
Parts Used:
WB24X829
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Unit would not come on.
removed access panal, found soft switch as discribed on your web site. removed and replaced.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donna from Denver, CO
Parts Used:
WB36X10071
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Glass cover for Light Bulb was cracked..
It was great...Thank you for having the part available...
Was this instruction helpful to you?
Thank you for voting!
Customer:
jerry from gulfport, MS
Parts Used:
WB36X10071
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
glass broken
replaced the glass
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patricia from Dublin, OH
Parts Used:
WB49X10063
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
glass cooking tray broke
I laid the new tray in the microwave. There was nothing to really install....but, the woman I spoke to in order to order the tray was terrific and I had the part in two days!! I would recommend this company every time!!!!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from East China Township, MI
Parts Used:
WB27X10928
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
All power to the microwave went out.
PartSelect had helpful repair instructions on-line which made the repair easier and faster. Unfortunately, there were other problems with the oven that immediately blew the new fuse I had just installed. It was then determined that additional repair would most likely cost almost as much as a new microwave.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PVM9215DK1BB