Models > JVM1540SP1SS > Instructions

JVM1540SP1SS General Electric Microwave - Instructions

Jump to:

All Instructions for the JVM1540SP1SS
46 - 60 of 163
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
GENE from SHREVEPORT, LA
Parts Used:
WB27X709
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
MICROWAVE SHUT OFF COMPLETELY
UNPLUG MIRCOWAVE.REMOVE THE HARDWARE, COVERS, AND DECONNECT THE CONTROL PANEL. REMOVE AND REPLACE VENT THERMOSTAT. REINSTALL EVERTHING IN REVERS ORDER. WORK FINE NOW. ADVISE IF YOUR FIRST TIME GET INSTRUCTIONS ON INTERNET SEARCH OR YOU TUBE
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from LAKE ELSINORE, CA
Parts Used:
WB27X10597
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Microwave wasn't heating up foods
Per instructions on part select.com website. But needs further repair because still doesn't heat food and pad is partially disabled.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathleen from Streamwood, IL
Parts Used:
WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Left light socket was damaged beyond repair
Handed the part to my son. He unscrewed 5 screws in the base of the microwave, it dropped down. The light mechanism was clearly in view. With the exception of some corrosion on the old piece, it was simple to remove and replace, put back together, screw back up and all worked fine.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lois from El Segundo, CA
Parts Used:
WB24X829
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave would turn on when door opened
Unscrewed numerous screws holding the "body/shell" to the microwave. Removed body. I then unplugged top door switch, replaced it with new one, and "tested" the new one. I fixed our $400 convection micro with an $18 switch. NICE!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lewis from HGHLNDS RANCH, CO
Parts Used:
WB27X11095
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Microwave ran, but wouldn't heat
I thought the thermal cutoff was out, ordered a new one. Turns out the TCO I was looking at was normally-open, and closes if overheated. My advice: No matter what your microwave is doing, start with a full inspection of each of the door switches. I did a continuity test, which initially passed; after replacing TCO didn't fix it, I found that one of hte door switches was intermittent - it had failed mechanically, would appear closed if jostled just right. After replacing that door switch the problem was fixed. Next time I'll start with the door switches - they're the easiest part to find, coulda gotten it locally - is most likely to fix the prob, and if not at least you've ruled them out for future troubleshooting.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from CICERO, IL
Parts Used:
WB08X10016
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Bulb broke in socket, socket had deteriorated beyond repair.
Phillips screws on bottom panel allowed me to install new socket and put electric connection back. Secured bottom panel and that was it.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from POWHATAN, VA
Parts Used:
WB24X830, WB24X829
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Austin, TX
Parts Used:
WB36X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Inside Bulb went out.
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from SHEFFIELD LK, OH
Parts Used:
WB27X709
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Total power loss of microwave
GE slate microwave approximately 2 years old. Completely dead. Power to outlet was good, no gfci was tripped. Started checking fuses, 250v ceramic fuse good, two fuses at the bottom behind the control panel. One on the left labeled 12 on the diagram tested no continuity. One on the right labeled 13 tested good with continuity. So i figured number 12 was bad. Got the part and turns out to be the wrong fuse. Part number was the same but the terminals were the wrong size. Im pretty sure GE has the diagram labeled wrong because i ordered number 13 and it was the right size. Just an FYI if you are ordering those fuses for your microwave that 12 and 13 on the diagram may be reversed. Anyway received the right fuse and tested the new fuse and it tests open continuity and did not fix my issue. Microwave is still dead. There are two other fuses in the back that i need to check so hopefully i find the issue. Hope this helps someone, remember one fuse behind the control panel tests open and the other tests closed and thats how it is suppose to function.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Big Rock, IL
Parts Used:
WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
bulb fused to jolder
removed electrical wires, unscrewed holder, inserted holder, attached wires, added bulb, and put cover back on.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jerene from Houston, TX
Parts Used:
WB36X10216
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Glass was broken
I took the cover off, and replaced the glass-- the difficult part, was ordering the glass..on the list of parts to order-- the description of the glass was mis-leading
10 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from Kirkwood, MO
Parts Used:
WB36X10003, WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light bulb burned out and assembly broke when trying to replace bulb
I used the internet and your directions to complete the repair. It was easy!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Enfield, CT
Parts Used:
WB27X10240
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
chattering noise/ burning smell
Removed control panel disconnected old capacitor installed new and returned the leads back on to the new. replaced control cover and tested
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nick from Edison, NJ
Parts Used:
WB06X10521
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
2 rack holders broke
used the Dremel Osciilating tool with small blade to quickly cut/remove the old rack holder and then inserted new hold. Took less then 5 minutes total.
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ernest from RIVERSIDE, CA
Parts Used:
WB24X830
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JVM1540SP1SS
46 - 60 of 163