JVM3670CF06 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave stays on when door opened
Removed control panel first then removed bracket holding door switches 8 screws total very easy fix ????
Was this instruction helpful to you?
Thank you for voting!
Microwave powered up when door was opened
After researching on line and watching installation videos, ordered all three switches and installed. Disassembly of microwave was simple, removing the bracket holding the switches was a little tricky, it sits behind a metal post and you have to angle and wiggle it out. One note of caution when replacing all three switches, be sure to install correct switch in correct location. Had two of one style switch and one of a second style, and put one in wrong place, causing microwave to power up again when door was opened. After thinking it through and doing a second disassembly, and double checking installation instructions, corrected problem and microwave now works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Clay from Kansas City, MO
- Parts Used:
- WB26X10037
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
A ratteling when the over was running
Unplugged the stirrer motor and the noise stopped. Therefore, replaced the stirrer motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronie from BRIARWOOD, NY
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave does not have power at all, though outlet has power
unplugged power cable / unhooked front vent / unscrew the monitor panel / slide up to dislodge / take the fuse out and put in the new one in / fuse is located right in front of monitor panel once its open might be covered by wirings / you can unpin the cables from the panel to make it easier for you just make sure to put it back properly or you can have somebody hold the panel for you. Installing the fuse is easy waiting for the parts is crazy......
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from VIPER, KY
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Blown fuse in microwave
One small Phillips screwdriver and one fuse puller (I used cord). Unplug unit. Remove the two screws on the vent face plate. Remove the one screw on the panel assembly. Gently let hang. Pull the fuse located on the upper left wall. Replace fuse. Reassemble.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gene from LaPorte, IN
- Parts Used:
- WB49X10063
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Tray was brokenwhen moving
opened the door and put in the tray!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from Clarksville, MD
- Parts Used:
- WB06X10144
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Turntable coupler became brittle and fractured
I simply pulled the old coupler off the moter shaft after removing glass turntable plate. The coupler lifted right out since it was fractured. Luckily all peices came out attached. Typically you would need to remove the bottom access panel on the microwave and remove the turntable motor to install the new coupler. However you can simply snap off the extra plastic piece that is molded to the coupler to allow for an easy push down onto the shaft from the inside of the microwave cooking area where the coupler fits onto the moter. Piece of cake. I don't believe there is any danger in shortcutting this because the weight of the glass plate will hold it in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from Fruit Heights, UT
- Parts Used:
- WB06X10144
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass turntable stoped turning due to broken coupler
Pulled out broken one with fingers, put on new one with fingers, it did not have anything preventing it from just slipping on. Didn't need to take anything apart to install me part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dorothy from MADISON, WI
- Parts Used:
- WB36X10213
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Awkward positive to work
Slowly and carefully to protect bulb
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maria from Edison, NJ
- Parts Used:
- WB06X10144
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
coupler was broken
removed the broken coupler and replaced it with the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Mesa, AZ
- Parts Used:
- WB26X10038
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Turntable no longer went around
I followed the instructions provided by others on-line who had done a similar repair. I removed a handful of screws, disconnected the wires from the old drive motor and connected them to the new drive, replaced the screws that held the drive motor in place, and those that held the bottom housing in place, and I was done. Literally took less than 10 minutes. If I had known earlier how easy it was, the microwave would have been fixed much earlier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Lillian, AL
- Parts Used:
- WB27X10195
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
microwave dead
First, potatoe burned up in microwave. Microwave
was dead. Took off cover and found maintaince repair pamphlet in envelope. Schematic showed one shot thermostat for fire. Ordered thermostat from you and installed it. Works fine.
was dead. Took off cover and found maintaince repair pamphlet in envelope. Schematic showed one shot thermostat for fire. Ordered thermostat from you and installed it. Works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Muskego, WI
- Parts Used:
- WB26X10038
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Cooking tray drive motor did not work.
Unpugged microwave. Removed the screws on the bottom cover of the micorwave. Unpugged drive motor and removed two screws from drive motor. Installed new motor and replaced the bottom cover, plugged in microwave . . . presto!
Installation was just as easy as numerous other customers indicated. Also, your service was as great as many other customers indicted . . . part was recieved in 2 business days. Thank you for great service and website.
Installation was just as easy as numerous other customers indicated. Also, your service was as great as many other customers indicted . . . part was recieved in 2 business days. Thank you for great service and website.
Was this instruction helpful to you?
Thank you for voting!
The microwave turntable rotates when the door is open.
This is sometimes described in other repair notes as "microwave 'runs' when door is open."
With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open.
Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower.
There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon.
Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open.
Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower.
There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon.
Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cody from Omaha, NE
- Parts Used:
- WB26X10038
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Turn table stoped functioning
Troubleshooting process:
Using a screw driver I opened the bottom of the unit using a Philips screwdriver and unhooked the drive motor electrical connector. Using a multimeter I checked to ensure power to the motor. This confirmed that the motor is bad and must be replaced.
Repair process:
After receiving new motor I removed the old motor and installed the new one using a Philips screwdriver and closed up the bottom cover.
It functioned good as new. Relatively cheap and very easy fix.
Using a screw driver I opened the bottom of the unit using a Philips screwdriver and unhooked the drive motor electrical connector. Using a multimeter I checked to ensure power to the motor. This confirmed that the motor is bad and must be replaced.
Repair process:
After receiving new motor I removed the old motor and installed the new one using a Philips screwdriver and closed up the bottom cover.
It functioned good as new. Relatively cheap and very easy fix.
Was this instruction helpful to you?
Thank you for voting!