JVM1631CH003 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- William from KINGMAN, AZ
- Parts Used:
- WB02X32720, WB24X25397
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
The power was on but the Microwave would not start.
This is an above the range microwave, use 2 people to remove it. I set it on a table and removed the outer cabinet. I then used jumper leads to discharge the capacitor. I removed the control panel (taking a picture to ensure proper wiring on assembly), then I removed the latch board. Once I had the latch board out I removed the monitor switch (which is the middle switch) and tested it for continuity. This is a normally closed switch. I tested the other two switches as well and found these (normally open) switches for continuity to be good and the monitor switch to have a short. This switch should show continuity when the door is open and should show no resistance when the door is closed. (Take care removing the switches) After I received the parts I installed them in the new Locker Holder and installed the latch board (ensure to follow the latch board adjustment steps located in the control board). I then attached the wiring to the control board and then plugged in the unit. I tested the unit to ensure it functioned correctly. I then installed the outer cabinet, and then installed the unit above the range (Use 2 people for this process). Overall an easy fix you just need to ensure you follow safety procedures (especially when dealing with capacitors.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from DENVER, CO
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alicia from ORANGE, CA
- Parts Used:
- WB07X10969
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
I had broken the clips that hold the vent in while cleaning it.
I ordered the part from this site (which was a little lower cost than another site but was described as a genuine GE part), and I looked up the instructions in my manual. It took about a week to get the new grille. There are 2 philips head screws attaching the grille. Just remove the screws, discard the old grille and put in the new grille with the same screws. The description on-line calls it a snap on grill which is a little misleading. It is attached with screws. I was fearful that it would not fit but it is identical to the old one. I am very pleased I did not have to replace the microwave even though it is 11 years old, it works.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from PONCA CITY, OK
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from COLORADO SPGS, CO
- Parts Used:
- WB27X10037, WB24X25397, WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Martin from Discovery Bay, CA
- Parts Used:
- WB06X10359
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
purchased a home that the microwave needed a grease filter
Used Google to locate parts dealers for GE.
Ordered from Partselect.
Part arrived a few days later and I easily put it in.
I thought the cost of this part was out of line but all others sold it for about the same.
Ordered from Partselect.
Part arrived a few days later and I easily put it in.
I thought the cost of this part was out of line but all others sold it for about the same.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dewey from MADISON, AL
- Parts Used:
- WB26X32629
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Burned out magnetron
Removed cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from HOLMEN, WI
- Parts Used:
- WB02X32720
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Microwave fan would come on when the door was opened and light would turn on. Determine that the Main Interlock Switch had gone bad.
Replaced all 3 switches and Holder for all 3 switches. All is working great now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from FULSHEAR, TX
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from APTOS, CA
- Parts Used:
- WB02X32720
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 30 - 60 mins
Received damaged parts
The first holder locker was shipped in a soft envelope and was damaged in shipping. I ordered a second holder locker with instructions to ship in a hard container and mentioned what happened to the first holder locker. The second holder locker was shipped also in a soft envelope and was received damaged.
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from CARY, NC
- Parts Used:
- WB02X32720
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers
Door would not indicate closed
Disassembly control panel and remove switch holder; test for micro switches for continuity. Holder had broken post on micro switch holder.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kip from POWELL, OH
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Salvador from Tucson, AZ
- Parts Used:
- WB26X10134
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
The Microwave was making a loud sound when the vent was turned-on
I removed the microwave from the wall and observed where the sound came from, I then removed the part that was held by two screws, then I order the part on Part Select it took three days to receive the part and in 5 minutes I installed it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Samuel from LAS VEGAS, NV
- Parts Used:
- WB02X11096
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Cracked plastic where the spring attaches
A 2 yr old could do this snap out. Snap in less then. 30 seconds . What a shame and rip off on appliance repair shops - I called to do this rediculsley 40 second job and the wantvv$125.00!9t more. Omg. I’m a senior/ no wonder God punished the world wit Covid 19! Too many nasty infair. Buii I needed and rip offs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Suzanne from POWELL, OH
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Microwave would not heat up
Part just snapped into place and wires were reattached.
Was this instruction helpful to you?
Thank you for voting!