Ronald from PONCA CITY, OK
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathy from SAN DIEGO, CA
Parts Used:
WB10X10021
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door latch broken
I read your instructions sent with the new latch. Looked at a couple videos online and it was VERY easy to change the part. Thanks so much?
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from COLORADO SPGS, CO
Parts Used:
WB27X10037, WB24X25397, WB24X10047
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James C from ARLINGTON, TX
Parts Used:
WB20X10048
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Bend, OR
Parts Used:
WB10X10021
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Door handle latch
We opened the microwave door and essentially with a straight screwdriver worked to "pop" the plastic frame off of the door. We tried to be less aggressive in our efforts and this paid off since we didn't break anything! The area we needed to work on was now exposed to put the new latch in. It took 2 hands rather than 3 to get the new latch attached and then wah-lah, It was done! Microwave works perfectly now. Great alternative to buying a new microwave!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherman from Memphis, TN
Parts Used:
WB10X10021
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The Door Latch on the Avantium Microwave Oven
I removed the door, by taking off the grill at the top. Then, take the puddy knife and screw driver and pry the facing off of the door. Please remember to be very careful because this is a sensitive piece. This is the most difficult part. It is a piece of cake after this. This should take about 15 minutes from beginning to end.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from WANTAGH, NY
Parts Used:
WB10X10021
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The door latch broke.
It was really easy. I am not a handy person but I followed a video and got it done quite quickly. It saved me a lot of money. The local appliance repair service charges a minimum of $75 just for the visit plus parts.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gilbert from TOMS RIVER, NJ
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Suzanne from POWELL, OH
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Microwave would not heat up
Part just snapped into place and wires were reattached.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gleason jay from ENCINITAS, CA
Parts Used:
WB36X10131
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave/Convection over lamp burnt.
Phillips screws out of the side; torx screws out of the bottom/back and slide the cover off of the back. The light is not visible but not hard to find: on the top left side mounted on a black plastic base with 1 phillips screw & stud holds other side. You can tell what the base looks like from the new part. GE probably wants you to call them to make the $-ha. Stay clear of any capacitors (shock) or chips (short) & touch the chassis to ground or if a tech, wear a ground strap.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from FULSHEAR, TX
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wilson from Pembroke Pines, FL
Parts Used:
WB10X10021
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
broken latch
We used the scresdriver(flat) to remove the frame inside the door, the remove several screws retaining the inner part of the door thenremoved the broken piece. We replaced the latch with the spring With a little patience, everything went fine. I broke one of the small tab, no big deal.
thanks, you saved me a lot of money/.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kip from POWELL, OH
Parts Used:
WB27X10928
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pearlie from Beulaville, NC
Parts Used:
WB27X10928
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followed them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
johnny from port orange, FL
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the SCA2000FBB01