Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Tijeras, NM
Parts Used:
WB26X32629
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Microwave would only heat food items to a warm condition
Removed microwave cover using screwdriver and anti tamper bit available at local hardware store. Megnetron had broken magnet making discovery of deffective part easy. Removed wire connector and three screws attaching magnetron to case, removed magnetron and installed new item in reverse order. Installed cover and made popcorn for operational check of microwave. Happy days..........
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from La Jolla, CA
Parts Used:
WB55X10828
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Plastic door frame broken
Remove vent above door by pulling out top and squeezing the top and bottom of vent together to unhook the bottom. Lift door off of hinge pins, may need to pry a little to clear the top of the pins. Carefully pry off black inner plastic liner and remove door handle screws. Check the new outer door frame to make sure that all the excess plastic has been removed - mine had a plug of plastic that interfered with the frame fit. Put the door handle back on before positioning the glass. Put the black plastic liner back on and make sure it is flush. Gently tap the edges of the outer door frame to fully seat the glass in the plastic frame. Put the door back on the hinge pins and re-install the vent.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Paso Robles, CA
Parts Used:
WB55X10828
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
plastic frame (white) cracked on bottom causing glass to slide down
Pop out inner frame on inside of door with small screw driver. Take off door handle two screws. Pop off old outer frame from inside tabs. Slide out glass and install in new frame carefully not to crack new door frame. Snap on to door and install door handle then inner frame.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Chandler, AZ
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
When trying to run, intermittently, the light would come on but the tray wouldn't rotate or cook. When the door was open, the tray would intermittently rotate.
I pulled out the unit and found 2 interlock switches that are depressed when the door closes. After cycling the door open/closed I found that one of the switches occasionally would stay depressed. The repair was easy (after I took off the panels so I could get to the switch) I simply removed 2 screws that attached the interlock switch assemblies to the main unit. Then I popped out the defective switch and popped in the new one. This did indeed fix my problem.
Was this instruction helpful to you?
Thank you for voting!