PVM9179DK6WW General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Tom from Carrollton, TX
- Parts Used:
- WB56X35363
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Installing New Microwave
Required removing the old unit and disconnecting the exhaust ductwork and drilling new holes for attachment to the cabinet
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sal from Center Moriches, NY
- Parts Used:
- WB27X44106
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Micro was not producing heat.
Removed unit from above range. (A two person task.) Removed display panel, disconnecting wires from plugins. Removed outer cover to access magnetron. Used camera to take photos before disconnecting other wires. Replaced magnetron and reconnected wires, double checking with photo. Tested prior to reinstalling. It works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from ELIZABETH, PA
- Parts Used:
- WB27X43766
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
broken microwave glass tray
ordered a new one form you...opened the microwave door and set it down
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Susana from PHOENIX, AZ
- Parts Used:
- WB26X10226
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Turn table motor malfunctioning, noisy and intermittent.
My oven is installed above the counter making it a bit difficult to reach the screws closest to the wall. Instructions should note that both harnesses need to be disconnected and that there are two screws, not one holding the motor. This one issue made it frustrating since that screw is located towards the back away from your vision. This is when the flash light and a bit of contortions were required.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from KINGMAN, AZ
- Parts Used:
- WB02X32720, WB24X25397
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
The power was on but the Microwave would not start.
This is an above the range microwave, use 2 people to remove it. I set it on a table and removed the outer cabinet. I then used jumper leads to discharge the capacitor. I removed the control panel (taking a picture to ensure proper wiring on assembly), then I removed the latch board. Once I had the latch board out I removed the monitor switch (which is the middle switch) and tested it for continuity. This is a normally closed switch. I tested the other two switches as well and found these (normally open) switches for continuity to be good and the monitor switch to have a short. This switch should show continuity when the door is open and should show no resistance when the door is closed. (Take care removing the switches) After I received the parts I installed them in the new Locker Holder and installed the latch board (ensure to follow the latch board adjustment steps located in the control board). I then attached the wiring to the control board and then plugged in the unit. I tested the unit to ensure it functioned correctly. I then installed the outer cabinet, and then installed the unit above the range (Use 2 people for this process). Overall an easy fix you just need to ensure you follow safety procedures (especially when dealing with capacitors.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from DENVER, CO
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from BLUFFTON, SC
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- johnny from port orange, FL
- Parts Used:
- WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from APTOS, CA
- Parts Used:
- WB02X32720
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 30 - 60 mins
Received damaged parts
The first holder locker was shipped in a soft envelope and was damaged in shipping. I ordered a second holder locker with instructions to ship in a hard container and mentioned what happened to the first holder locker. The second holder locker was shipped also in a soft envelope and was received damaged.
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Wesley Chapel, FL
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from MINNEAPOLIS, MN
- Parts Used:
- WB02X32720
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Changing door switch
When removing a non-working door switch, you will see a hooked piece of plastic on the holder locker that looks like a latch. If you try to pull it back in order to either remove the bad switch or install a good one, it will likely break. Instead, you need to pivot the switch (It pivots on a little post which is fitted into a hole at the corner of the switch) out of position so that it is not held back by the 'latch'. Then lift the switch out. If you have to use lots of force anything, you're doing something wrong. Reverse all this when installing the new switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from MISSION VIEJO, CA
- Parts Used:
- WB02X32720
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Holder bracket broken so Door swithch could not be activated
Part arrived next day! Thank you Parts Select. Holder bracket on older GE microwave was broken so MW would not start because door latch did not activate door switch. Removed front panel unplugged all the wiring (after I had taken a picture) to gain access to the holder bracket. Unplugged the three door switches. Removed two screws that held the holder bracket. Installed three new door switches into the new holder bracket. Positioned the bracket behind the frame and screwed back in the two screws. Snapped in this seven wire attachments, set the control panel back in the microwave and secured it with two screws. I only needed one screwdriver and one needle nose plier to remove the wire attachment from a door switch which made it easier to remove. 40 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ira from LIVINGSTON, LA
- Parts Used:
- WB27X35382
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Food wouldn't heat up
Googled problem, removed diode, checked with meter and it was open, ordered new diode, checked new diode and it read open, installed. Any way, it didn't work. Went and bought new microwave!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Darin from SAN DIEGO, CA
- Parts Used:
- WB27X35382
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
No heat. No unusual noise. Appers to function other than no heat
Multimeter checked/confirmed switches, sensors, and fuse first. All good. High power diode was bad - Replaced. Still no heat but now loud "MMMMM" noise when running. This means either the capacitor is also bad and/or magnetron.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from FULSHEAR, TX
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this instruction helpful to you?
Thank you for voting!