JES1289SK01 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Masontown, PA
- Parts Used:
- WB27X10568
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Completely Dead
After opening the case (the most difficult part of the job), tested the fuse (good) next in line on the power lead was the "flame sensor". With my ohmmeter it read open. The schematic noted that it opens at 212 degrees and closes at 32. Put it in the freezer for 15-20 minutes while I ordered a replacement. Upon rechecking, it had reset. Reinstalled it and everything works fine. I did receive the new one and it's on the shelf, just in case.
Was this instruction helpful to you?