Models > EMO3000CCC03 > Instructions

EMO3000CCC03 General Electric Microwave - Instructions

Jump to:

All Instructions for the EMO3000CCC03
61 - 75 of 405
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Fort Smith, AR
Parts Used:
WB36X10003
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Bulb burned ot
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Bakersfield, CA
Parts Used:
WB06X10138
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Sparked at the coupler, burnt
Using the exploded parts view I removed three Philips screws from the lower plate (the screws are located on the front edge of the panel that holds the air filters). Slide the lower panel forward slightly and allow it to swing down. Remove the amphenol connector to the motor and hood lights by pressing the sides of the plastic clip and place the lower panel to one side out of the way. f you intend to clean the lower panel in a dishwasher remove all electrical components before doing so (bend back the clips holding the wires in place and remove the lamps, remove the Philips screws holding the lamp holders); note: these are the only screws with a short shoulder on them, make sure they go back in the same place to hold the lamp holder to prevent damage to the holder). Remove the Philips screw holding the turn table motor in place. Slide the entire motor assembly to one side to allow the motor shaft to slide off the coupler. With the oven door open, remove the old coupling by sliding it to one side to clear the retainer. Insert the new coupling and replace the motor making sure you align the motor shaft with the flat side of the coupling. If you have cleaned the lower assembly in the dishwasher or by hand make sure all parts are dry before reassembly (reinstall the lamp holders and the wiring assembly. Reconnect the amphenol connector (it can only plug in one way by nature of design). Slide the back of the lower assembly into the channel at the back of the oven and replace the three screws holding the lower panel in place.
Now you have saved your self the cost of a service call or possibly a new microwave you can use this as supporting evidence that you can afford the new 20" monitor for your PC. Test out the repair and make your spouse a cup of hot coffee or cocoa to brag on yourself and make your sales pitch.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Enid from Double Springs, AL
Parts Used:
WB06X10139
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Roller guide for microwave turntable broke and could not be used.
Simply ordered a replacement part that was quickly and coveniently mailed to my home.
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
selwyn from inglewood, CA
Parts Used:
WB39X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Glass Carousel Cooking Tray Broke
I replaced old tray with new. Received replacement part in two days. I was surprised at the quick response time. The part ordered was right the first time.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Austin, TX
Parts Used:
WB36X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Inside Bulb went out.
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eugene from Lakeland, FL
Parts Used:
WB39X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Dropped and broke glass carousel tray
Put it in place. Ordered replacement over internet on Wednesday and part arrived Friday. Very fast service!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brent from Sacramento, CA
Parts Used:
WB26X10038
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Glass turntable drive motor failure
Removed bottom cover of microwave, involved removing 7 screws, removed turntable motor, involved disconnecting wire harness plug, and 2 screws, connnected wiring to new motor and reinstalled with original hardware
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from CICERO, IL
Parts Used:
WB08X10016
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Bulb broke in socket, socket had deteriorated beyond repair.
Phillips screws on bottom panel allowed me to install new socket and put electric connection back. Secured bottom panel and that was it.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathleen from Streamwood, IL
Parts Used:
WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Left light socket was damaged beyond repair
Handed the part to my son. He unscrewed 5 screws in the base of the microwave, it dropped down. The light mechanism was clearly in view. With the exception of some corrosion on the old piece, it was simple to remove and replace, put back together, screw back up and all worked fine.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Marco Island, FL
Parts Used:
WB39X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Glass carousel cooking tray shattered
It took less then 10 minutes to order. Received new part with 3 days
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Big Rock, IL
Parts Used:
WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
bulb fused to jolder
removed electrical wires, unscrewed holder, inserted holder, attached wires, added bulb, and put cover back on.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Mableton, GA
Parts Used:
WB26X10038
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
noise eminating from carousel
I removed 4 screw from the under carriage of the microwave then, removed the 2 screws from the motor, replaced the motor and replaced the screws. It was so easy it took only 4 minutes to perform, better than replacing the whole unit (microwave) and less expensive too. i only wish it was made in the US, I wouldn't mind to spend a little more.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from Kirkwood, MO
Parts Used:
WB36X10003, WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light bulb burned out and assembly broke when trying to replace bulb
I used the internet and your directions to complete the repair. It was easy!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Columbus, OH
Parts Used:
WB39X10003
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The cooking tray cracked.
First I replaced the cracked cooking tray and I was done.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Divina from Grand Rapids, MI
Parts Used:
WB36X10003, WB08X10016
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Both under mount lights were burned out
Unscrewed bottom panel, then unscrewed light socket, then replaced with new socket and bulb. Reattached socket and panel.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the EMO3000CCC03
61 - 75 of 405