Customer:
Henry from NORWALK, CT
Parts Used:
WB10X27080, WB14X10049
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Microwave door was hard to open
1. Take out the case by unscrew 8 screws on the back and side of the case
2. Take out the control panel by unscrew 1 screw on the top and slide up
3. Take out the latch by unscrew 2 screws, and slide out 3 electric switches that clipped on the latch
4. Clip the switches onto the new latch
5. Slide in lever switch into latch
6. Put back the latch
7. Put back the control panel
8. Put back the case
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from WESLEY CHAPEL, FL
Parts Used:
WB14X10049
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Door locks. Not opening.
Slide a Butter knife at left side by open push knob door will open. Then open all screws from top cover push cover top side front way then door locks Bracket have 3 microswitch pulls out switches mark them top medium and bottom. Remove 3 screws holding brackets will come out. On bottom see a Cam has 1/4” holes can holding Saft broken then install new door lock bracket install microswitch put 3screw and slide Cam on saft . I put a small screw on saft to hold cam on place. There was no screw . That’s why cam saft was broke. Put top cover tight all the screws and door lock fixed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Moin from SCOTTSDALE, AZ
Parts Used:
WB24X10190
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
WHEN. YOU OPEN THE DOOR THE TURN TABLE WAS CONSTANTLY RUNNING
REPLACE SWITCH -STAND ON (NOT THE SWITCH-MONITOR) THERE ARE TWO OF THESE SWITCHES THE TOP ONE WAS DEFECTIVE.
THE ON OFF SWITCH BUTTON ON THE SWITCH WAS BROKEN
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from KIRKLAND, WA
Parts Used:
WB39X10034
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Installed waveguide
Inserted the waveguide into the slots on the side of microwave.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Juan from FONTANA, CA
Parts Used:
WB27X11210
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My microwave started tripping the breaker
Yes, it started tripping the breaker and at the end it wouldn't work at all, I started checking continuity on all door switches everything checked good, then I proceeded to check the thermostats and found out that one didnt have continuity so I replaced it. Every thing works good except that as soon as I pluged the microwave to the outlet the exhaust fan comes on and does not shut off. Does anyone known why or do I need to change something else.
Thanks
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PEB7227DL3WW