Models > SCB1001KS > Instructions

SCB1001KS General Electric Microwave - Instructions

Jump to:

All Instructions for the SCB1001KS
46 - 60 of 135
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
dennis from harbor springs, MI
Parts Used:
WB25X10019
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Halogen lamps did not light-burned out
Removed the light cover screw with a Phillips screwdriver. Removed the lamps from the packaging just enough to free up the 2 prongs for fitting in the socket. Make sure the power is in the "off position". Install the bulbs one at a time by lining up the 2 sockets (Very important not to touch the halogen bulb glass surface while installing them). Energize the light switch to check operation of the new bulbs.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from DENVER, CO
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vincent from Mount Sinai, NY
Parts Used:
WB25X10019
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Both my microwave halogen lamps went out.
Using a phillips screwdriver I opened the panel in which the two lamps are located and easily removed the lamps. I ordered them through the internet and was pleasantly surprised when I received them the next day.
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Lawrenceville, GA
Parts Used:
WB25X10019
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light bulb went out and I was unable to find the right size locally.
Had to use a screw driver to remove the cover to replace the bulb. Worked great and your service was great. Probably didn't take more than 5 minutes.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from COLORADO SPGS, CO
Parts Used:
WB27X10037, WB24X25397, WB24X10047
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James C from ARLINGTON, TX
Parts Used:
WB20X10048
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ezequiel from Lithia, FL
Parts Used:
WB27X10856
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Blank LCD screen
.Shut breaker to microwave
. Remove two screws on each side of microwave cabinet frame holding it to the wood frame
. Get assistance in pulling microwave out of cabinet
.unplug power cable before pulling microwave completely out of cabinet
. Microwave has two separate panels top and sides removed all screws around frame along the door and sides
. Remove top steel panel
. Remove sides
. Locate screws around the electrical board screen just behind the front cover
. Use small flat head screwdriver to move plastic fasteners on each side of the electrical to release the board.
. Identify the LCD screen board and remove two screws on each side unplug the wire harness from the board.
. Lift LCD board off the two set pins
. Replace board
. Replace screws
. Plug harness back into board
. Reassemble electrical board back into display panel. Pay attention to re-engage the two plastic clips before replacing screws.
. Once panel is completely replaced.
. Resemble all panels in reverse order
. Test microwave before installing unit back into cabinet.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from SAINT LOUIS, MO
Parts Used:
WB25X10019
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
light bulb burned out
Remove 1 screw, remove light bulb and replace and replace screw. No problem.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Suzanne from POWELL, OH
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Microwave would not heat up
Part just snapped into place and wires were reattached.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gilbert from TOMS RIVER, NJ
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from BLUFFTON, SC
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathy from SARASOTA, FL
Parts Used:
WB06X10638
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Canopy Mica broke off piece that secures to the top of the micro
Slips in easily. Line up the tabs with the brackets and pop in.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from FULSHEAR, TX
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
johnny from port orange, FL
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
bart from new sarpy, LA
Parts Used:
WB27X11033
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Try to heat food and fuse would blow.
Went on Youtube and pulled up how to fix a microwave.
8 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the SCB1001KS
46 - 60 of 135