Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Muhammad from Jersey City, NJ
Parts Used:
WPR9800486
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
No Heating.
Information provided on the web site by Part Select, were helpful and encouraging to select and buy the part needed to repair the appliance. No doubt, a skilled person having background in the repair of appliances should attend such repair job.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Palmer Lake, CO
Parts Used:
4392027
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Microwave worked intermittently
The door was not engaging the micro switches properly no doubt from 10+ years of wear. The upper switch removed fairly easily but take care not to tweak the plastic brace too much or it will snap. The lower one was the tricky one. After much examination I noticed that the trick to remove it was underneath the brace. Take a butter knife (no joke) and insert it just under the old micro switch and gently press down twisting the micro switch every so slightly til it releases. The replacements snap back in with no trouble. The microwave is working much better now, though not perfect.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M. J. from Chester, NH
Parts Used:
WP8172138
Difficulty Level:
Really Easy
Total Repair Time:
More than 2 hours
I broke the dish in my microwave unit.
I simply went on line to Part Select, placed my order, made payment, and was astonished to see the package with a new dish sitting on my doorstep the next day.Great service.
Was this instruction helpful to you?
Thank you for voting!
Customer:
outstanding from Galena, MD
Parts Used:
WPR9800486
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
microwave would not heat.
hardest part was taking the microwave down off of the wall to gain access to the diode. Thought if was the transformer but ended up being just a blown diode. remove and replace and bench test. that part took 15 minutes . moral of the story don't boil water under the side of the microwave that holds the electric components.
Was this instruction helpful to you?
Thank you for voting!