Customer:
Aaron from BLUE RIDGE, TX
Parts Used:
WB26X32629
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave function not working
1) Removed 4 screws securing the microwave to the cabinet.2) Slid microwave out, unplugged and placed on a work surface that allowed lower trim to hang over. 3a) Removed two screws and removed the cover on top of the oven. 3b) Unplugged high voltage plug from Magnatron. 4) Removed wires from overtemp fuse mounted to Magnatron. 5) Removed the four screws securing the Magnatron to the oven. 6) Removed Manatron. It's a tight fit, but can be done without removing anything else. 7) Replaced Magnatron. This is where I needed the magnetic part retrieval tool. The nature of a Magnatron is the use of strong magnets surrounding the tube. Getting the four screws back into place wasn't possible with just a normal magnetic screwdriver tip. I used the retrieval tool to position the screws back in place. Be sure to not initially tighten any screw completely, until they can be evenly tightened. This ensures correct compression/seating of the shielding material near the neck of the tube. 8) Reverse removal steps. Plugged in and tested microwave function on a cup of tap water. 9) Reinstated in cabinet and got a big thank you kiss from the wife!
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from VIPER, KY
Parts Used:
WB27X10928
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Blown fuse in microwave
One small Phillips screwdriver and one fuse puller (I used cord). Unplug unit. Remove the two screws on the vent face plate. Remove the one screw on the panel assembly. Gently let hang. Pull the fuse located on the upper left wall. Replace fuse. Reassemble.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Springfield, VA
Parts Used:
WB27X10857
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Oven wouldn't sensor reheat & error code on display
I looked at the exploded pic on your web site to find the location of the sensor. Next I removed the cover by unscrewing 15 screws then swaped the sensor and re assembled! Works great! Fixing it my self I saved at least 150$ and did not have to wait all day for a repair man who probaly would not have the part on the first visit.
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Reid from LITTLETON, CO
Parts Used:
WB26X32629
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Sparking from the magnetron
Symptom: Terrible sparking coming from the right side of the microwave even with nothing in the microwave. The part that was behind the cover was the business end of what I learned was the magnetron,

Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.

I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharry from Lititz, PA
Parts Used:
WB02X35488
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Microwave bulb was burnt out
It is easy to repair the burnt out bulb if one has the correct bulb. Your website is very user friendly and your service is great. I was not able to replace the bulb at this time because our RV is at the repair shop for some other matters. I am sure the installation of the new bulb will go smoothly. Thanks for asking. Sharry Kiehl
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from PIEDMONT, CA
Parts Used:
WB26X32629
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
runs but does not heat
I removed the main cover ( torx security bit required) and tested the magnetron, capacitor, diode and door interlock switches according to instructions found on the internet. The capacitor and diode tested good but the magnetron looked burnt and corroded on the tip. The magnetron I received was an exact replacement for the original. It was easy to replace the magnetron which arrived in 2 days standard shipping. I also cleaned the fan while I had access to the inside area. Hoping to get another 18 years use from the microwave!
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dottie from NEW MILFORD, CT
Parts Used:
WB02X35488
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Replaced under hood surface light bulb
Very easy to replace. This replacement part is the perfect fit for my microwave since the original part has been discontinued. It does have the night light and bright light feature.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES T from PEWAUKEE, WI
Parts Used:
WB27X10856
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Display did not lightup but the microwave oven functioned.
I did not have to replace the part. I turn the fuse off and waited 5 minutes and turned it back on. The display came back on. I saw this recommendation on your web site after I ordered the part. You should do this before you order the part.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from MAGNOLIA, TX
Parts Used:
WB06X10638
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The part was burnt and was causing sparking inside the microwave
Removed the old canopy mica, it has tabs that slip into slots on the top of the microwave. Then installed the new part, the tabs are inserted into the same slots.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from LOUISVILLE, KY
Parts Used:
WB26X10193
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Turntable motor was making noise
Unscrewed and dropped the bottom panel of the Advantium on its rear hinge, disconnected the light and the motor, removed the motor screws, and replaced the motor. Very simple.
However, not related to the Advantium or the motor, trim had been applied to the bottom of the wall cabinets after installation of the Advantium. This trim prevented the lowering of the panel (and future removal of the whole oven), so I had to chisel and file and repaint the trim to get it out of the way.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from PONCA CITY, OK
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James C from ARLINGTON, TX
Parts Used:
WB20X10048
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathy from SARASOTA, FL
Parts Used:
WB06X10638
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Canopy Mica broke off piece that secures to the top of the micro
Slips in easily. Line up the tabs with the brackets and pop in.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kip from POWELL, OH
Parts Used:
WB27X10928
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DEBORAH from SUMMERTON, SC
Parts Used:
WB02X35488
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Bulb burnt out
Followed instructions that came with bulb I ordered and could not have been easier. Will use this site again.