Tom from DENVER, CO
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from HAVERTOWN, PA
Parts Used:
WB26X23813
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Fan motor not operating
Removed screws from front of oven, placed a table under oven 2” below, places two rollers on table and pulled out the oven. Removed screws, replaced fan and reassembled. Move into place and secured front. Cleared faults and worked perfectly.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darin from SAN DIEGO, CA
Parts Used:
WB27X35382
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
No heat. No unusual noise. Appers to function other than no heat
Multimeter checked/confirmed switches, sensors, and fuse first. All good. High power diode was bad - Replaced. Still no heat but now loud "MMMMM" noise when running. This means either the capacitor is also bad and/or magnetron.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from LOUISVILLE, KY
Parts Used:
WB26X10193
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Turntable motor was making noise
Unscrewed and dropped the bottom panel of the Advantium on its rear hinge, disconnected the light and the motor, removed the motor screws, and replaced the motor. Very simple.
However, not related to the Advantium or the motor, trim had been applied to the bottom of the wall cabinets after installation of the Advantium. This trim prevented the lowering of the panel (and future removal of the whole oven), so I had to chisel and file and repaint the trim to get it out of the way.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from Wesley Chapel, FL
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from SOUTHBURY, CT
Parts Used:
WB20T10024
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Temp probe was defective
Threw the old one out - plugged the new one in. Steak came out just as ordered - medium rare.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from FULSHEAR, TX
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from COLUMBIA, MD
Parts Used:
WB08X10057
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Replace bulb under microwave
Part Select sent the wrong part I did not realize it until prong broke off one of the bulbs. They sent 130v instead of 120v. Return bulbs awaiting resolution.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Suzanne from POWELL, OH
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Microwave would not heat up
Part just snapped into place and wires were reattached.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ira from LIVINGSTON, LA
Parts Used:
WB27X35382
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Food wouldn't heat up
Googled problem, removed diode, checked with meter and it was open, ordered new diode, checked new diode and it read open, installed. Any way, it didn't work. Went and bought new microwave!!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dewey from MADISON, AL
Parts Used:
WB26X32629
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Burned out magnetron
Removed cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert P. from DEDHAM, MA
Parts Used:
WB26X10193
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
MOTOR STILL DOES NOT TURN
PER YOUR INSTRUCTION
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
johnny from port orange, FL
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from BLUFFTON, SC
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tony from ITHACA, MI
Parts Used:
WB20X10048
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Thermostat quit.
Checked all sensors with a multi-meter, found the thermostat to be the problem, no continuity.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!