Models > GI1500PHB7 > Instructions

GI1500PHB7 Whirlpool Ice Maker - Instructions

Jump to:

All Instructions for the GI1500PHB7
61 - 75 of 89
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Paul from Paige, TX
Parts Used:
WPW10503764
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker would not make Ice.
Took out one strap support with a nut driver, unplugged the device and plugged in the new one. Reinstalled the support strap. Job complete.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Safety Harbor, FL
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Our ice machine froze up when we were away and burnt out the motor.
We guessed what the problem was and we were extremely fortunate that we guessed correctly. The part was not technically difficult to install just a little awkward to get to. My husband had no trouble although he did take the machine out of it's space and lay it flat on the floor. One benefit of this process was being able to clean some of the areas that are almost impossible to get to when the motor is in place. It was well worth the extra shipping charge to get it before the weekend.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cypress, TX
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Circulation Pump not working
Follow the instructions already submitted by others. As mentioned be sure to place towel inside to cover the drain. My 3-wire electrical connector also had some corrosion build-up so I had to remove the bracket holding the connecter cut the 3-wires and install a new connector. Not a big deal, you are just working in a small enclosed area. Pulling the entire unit out and either elevating or tilting back helps with the access. Be sure to check drain connection in the back of the unit when putting back in place. Having a headband light helps for entire repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Juergen from Belle Chasse, LA
Parts Used:
WP2313637
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Anchorage, KY
Parts Used:
4387020
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
cutting grid wire broke
Bought new wire, strung it end to end and fastened it at each end.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Rensselaer, NY
Parts Used:
W10822259
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Socket set
condenser fan motor quit
Technically, the repair did not require specialized knowledge. However, replacement of the motor required some effort. Because the motor is located at the bottom of the unit in an area with copper tubing & wiring hindering access it was physically difficult to remove and then replace the motor. A problem arose because the shaft on the replacement motor was larger than the original motor's. Thus the fan would not fit on the new motor. Luckily, I found a fan locally that fit the motor. It would be very helpful if a fan was included in the motor kit. The ref. is now running smoothly
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raylene from Taylorsville, UT
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
had to replace Scotsman ice maker pump
didn't go well at first. Got it all hooked up relatively easily but it didn't work. Called customer service who suggested hooking pump up to other power source to be sure it worked. It still didn't work. After closer inspection a connection wasn't hooked up on pump. After connecting got it back in about 30 min. Working like a charm now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Claudia from Watauga, TX
Parts Used:
W10822259
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Condensor fan motor not working
Removed the back lower cover, behind the fridge. Uncliped the wiring. Removed the motor, (3 Screws).I did check the new motor before removal of the old one, to verify the older motor was the problem. After removal of the fan & motor. Removed the fan and placed it on the new motor, three screws later, plugged up the wiring, (I didn't changout the wiring, and the Refrigerator is good as new.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Groton, CT
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Water circulation pump not working
I determined the pump was not working by running the ice maker. After it started a cycle, I could fell the underside of the cold plate to insure it was indeed cold, but no water was flowing.
First, be sure the water pump electrical plug is in., it releases by pressing together the tabs at the ends, not sides.
To replace the pump, turn off the water supply and cover the drain hole at the bottom of the ice bin so you don’t drop parts down it. The screw-plug at the bottom of the water tank or a quarter will do.
Remove the water tank below the pump by taking out the thumbscrews at both ends. You can then see the hose at the bottom of the pump. If it is off, that may be the problem.
To remove the pump, pull the fill hose to the left out of the slot and bend it behind the pump to get it out of the way. Unplug the electrical connector and the pump hose. There are three ¼” hex head screws, teo on the side wall, one in back. The middle one is the hardest to access. I used both a nut driver and a socket wrench with a 4” extension.
When installing the new pump, be sure to plug in the electrical connector, the discharge hose at the bottom and position the fill tube as you found it. Forget any of these and nothing works. Re-install the water tank, replace the drain plug and turn on the water supply, in that order.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Drew from Birmingham, AL
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Socket set
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GI1500PHB7
61 - 75 of 89