GI1500XHB6 Whirlpool Ice Maker - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- harold from cleveland, TX
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Waterford, WI
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Failed cooling fan
The repair was simple. Unplug the refrigerator, unplug the power connector from the fan and remove 3 screws. I removed the fan blade clip with the pliers and cleaned it off. Reversed the process, cleaned all the dust out with my shop vac and all works perfectly now. It took longer to pull the fridge out of it's normal position than to perform the repair. Every day it continues to work is one more day I don't spend $2000 or more on a replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CIndy from Leander, AL
- Parts Used:
- WPW10683580
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
ice maker making little to no ice
I installed the new thermistor and although I can see a difference in the size and thickness of the cubes that are being made, the machine still does not make a sufficient amount of ice daily. Still trying to find the correct item that needs to be replaced
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ALAN from KENNETT, MO
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
macnine was producing ice but would not cut into cubes
remove the front cover by removing two screws. then remove two screws with a nut driver on each side. unplug the wireing harness from the top of the unit (may need pliers for this) the pull the unit out. then slide the new unit in, connect the wireing harness, install two side screws, and install the front cover and wham you will have ice in about 30 minutes. thanks parts select. you were very easy to deal with
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Hollister, CA
- Parts Used:
- W10822259
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
Noisy Motor
Pulled refrigerator away fom wall. Removed cardboard cover at back bottom to reveal fan motor.The space available to remove the motor from the bracket is very limited, so smaller hands will be a plus! Tried to get a nut wrench on motor but there was hardly enough room. Finally was able to use a socket set to remove bolts. I would suggest you spray a solvent on the motor mount bolts and seat them in the new motor first. It was near to impossible to get them started in the mount, without seating them first. The electrical clip that connects to the motor fit on the new motor, so I did not have to splice any wiring. This made the job a little easier. Finally, replaced cardboard cover and moved refrigerator back against the wall. .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from Mount Juliet, TN
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Condensor fan stopped working, refrigerator got hot.
1. Unplug the refrigerator. 2. Remove the back cover at the bottom of the refrigerator. 3. Remove the two screws holding the vertical black bracket the fan is mounted to. This allows the bracket to move easily. The bracket does not have to be removed. 4. Removed the four screws holding the fan bracket to the vertical bracket. 5. Unplug the power connector from the fan motor. 6. Remove the entire fan bracket assembly from the refrigerator. 7. Remove the 4 screws holding the fan motor to the fan motor bracket and unmount the fan motor. 8. Remove the nut holding the fan blade to the fan motor and remove the fan blade. 9. Reverse the process, mounting the fan blade to the new motor, screw the motor to the bracket, screw the bracket to the vertical bracket, screw the vertical bracket to the refrigerator and plug the power connector back into the motor. I did not have to use any of the extra mounting hardware or electrical hardware provided with the kit. It might be a good idea to purchase a new fan blade with the motor kit, the fan blade can get pretty grungy. I cleaned the fan blade with some degreaser before remounting it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- doug from atlanta, GA
- Parts Used:
- WP2217220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Water was not circulating onto freezing plate
Simple, remove water reservoir (2 screws). Remove pump cover (1 screw). Remove 2 screws on bracket holding pump and unplug pump. My wiring was somewhat corroded and it took a bit of pulling to unplug. When you replace with new motor make sure to snap in new plug snug or it will not start up. Reassemble and away you go.Making ice no problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Cardiff, CA
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refridgerator would not stay cool, eventually over burdened the freezer.
Over a period of weeks I watched my fridge grand to a halt. It was...saddening. I felt helpless, there was nothing I could do and I wasn't prepared to pull in a repairman. Upon it's departure from being affective (broke) I made up my mind to purchase a new one!! Flash-forward five minutes n the internet ...motivator by high costs, I altered my thinking and visited You Tube for a fix-it video. After a quick search I came across a clip that took me to the heart of the problem. It was THAT easy. Wow!! I followed the instructions and quickly learned the failure had to do with a small, light weight fan that's role was to pull heat from the condenser--it had ceased to work. While waiting for the part, I let a small fan blow on the condenser to dissipate the heat. The fridge roared to life!! Like a charm!! When the new fan body arrived I placed the blade from the old fan on it and installed it (the fan did not come with bolts and the holes were not threaded) using sheet metal screws. It immediately came started performing again and has been doing a superb job ever since. I easily saved $800 in costs going this route!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BRUCE from KRUM, TX
- Parts Used:
- W10822259
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Unit Running Hot
Insalled fan motor,problem went away. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Friendswood, TX
- Parts Used:
- WP2217220
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Hard water deposits salted pump motor
Disconnect water line and power cord, Remove scoop holder, water reservoir and shield around pump to access pump, removed hose connected to pump then removed pump (3- 1/4" hex screws) and disconnected wire harness and 1/4" plastic water line attached to pump bracket, reverse process
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Norman, OK
- Parts Used:
- W10822259
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set, Wrench set
Fan motor making noise then failed. Ice maker stopped making ice
Once I determined easier access to the fan motor, I removed the three fan motor screws that held the motor on place. After removing the motor I remove the fan blade assembly held by one nut and reattached to the new motor. I then reattached the new motor with 3 new screws which were provide and reattached the power cord with the cord clip and began reassembling the icemaker housing, then moved the unit back in place which was installed under counter. I could do this repair in less than 45 minutes now that I have done it once. I saved several hundred $ from the original estimate and the parts were delivered in 2 days after I ordered online. This is definitely a DIY project!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andrew from Mission Viejo, CA
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Fan motor making awful noise, not turning very fast
Fan was barely rotating. So unplugged, removed back cover, removed fan and motor from frame work. Removed fan blade from motor shaft. Spun motor shaft which seemed fine. Pryed off back cover of motor to find a large but dry felt washer and a helical capillery slot formed into the motor shaft for carring oil from felt washer to the bearings. Added 30 wt motor oil and some 3in1 oil to felt and reassembled motor, fan and frame work. Plugged in power chord after getting rid of dust and dog hear on coils and is working like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Missy from Naples, FL
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Not making cubes
Wires in cutter grid were broken and wouldn't freeze/cut ice. Replaced with the new ice cutter grid that came completely assembled. Put it in with a screwdriver in less than 10 minutes. Ice cubes ready in 45 minutes. Repair guy told me it would be $455 for him to repair it. With shipping, mine was $133 and 10 minutes of my time. Well worth doing it myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Paige, TX
- Parts Used:
- WPW10503764
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker would not make Ice.
Took out one strap support with a nut driver, unplugged the device and plugged in the new one. Reinstalled the support strap. Job complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronnie from Corpus Christi, TX
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My undercounter ice machine grid cutter wire broke
I removed the two screws that hold the shield in front of the grid and put them aside allowing access to the grid. I then removed the two screws that hold the grid in place. I unplugged the connector and then pulled it out. I reversed the process to reassemble and powered up the unit. I now have ice again. This whole process probably took me 15-20 minutes to do the install.
Was this instruction helpful to you?
Thank you for voting!