Chris from Brentwood, TN
Parts Used:
W10823511
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Broken Water Nozzle at Door
(1) Ordered PS371704 from PartSelect! Best advice EVER! (2) Unplugged refrigerator (since the water solenoid on the back of the refrigerator is powered to switch ON the water, you NEVER have to turn off the water!) (3) Pull off the refrigerator's bottom grill. (4) With a small saucer under the fittings, unscrew the black and white tube fitting. There is only one nut to remove on the white tubing side. You'll need to undo the compression fitting on the black tubing and slide off the compression nut. You'll need to MAKE SURE you keep these nuts and replace onto the black and white tubing the SAME WAY you took them off. You'll NOT need to use nut drivers as finger tight is the key. Too hard and you'll ruin these plastic nuts. You should get only about 1/8 cup or less of water during this whole exercise. (5) Cut off the old, broken water nozzle. (4) Find a screw of the appropriate size to fit tightly 1/2 way inside the new tubing (this is to ensure your old and new tubing are connected to feed through the door). If screw is not tight within the tubing, wrap part of a plastic (thin) sack around this screw a couple of times and force into the tubing. You'll, of course, then need to use the hacksaw to cut the head off the screw as you'll be forcing the other half of the screw into the old cut tubing (6) Chase the dog out of the kitchen and cajole your wife (significant other) to push the newly joined tubes through the top of the dispenser, through the door and out the bottom as you will be gently PULLING on this old tubing from the bottom until the new tubing pops through the doors bottom. (7) Once this new tubing is out, you will separate the old tubing and, using the nuts in the proper sequence, connect this new tubing to the white tubing. (8) Plug the refrigerator back in and test flow the water. Check to ensure the plastic nuts have no leakage ... button up the bottom grill ... and enjoy the fresh water! PS> Don't forget to praise the wife (significant other) and give the dog a treat for staying out of your face!!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Huntsville, AL
Parts Used:
W11566407, WPW10548509, W11566405
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
One of the circulation pumps was going bad and making a loud noise.
I replaced the two pumps, since both were the same design...figuring if one went bad then the other would soon go bad...and then I also replace the water level sensor. All had quick connect plugs. The time is just taking apart the various pieces, cleaning, installing the new pumps and sensor, then reassembling.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Atlee from Jupiter, FL
Parts Used:
WP2149705
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
broken light switch
Figured out You have to pop off the cocer than remove the 1/4 hex head screws only not the philips ones
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barton from Ringgold, GA
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
leaking water inlet valve
Received replacement valve ~ 3 days, easily replaced in less than 15min, works great
4 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lindey from Austin, TX
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freeze ruptured inlet valve
Simple to replace. Next fall I will be sure to drain the outdoor icemake and shut it down for the winter.
7 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
otis from frenchburg, KY
Parts Used:
WPW10217917
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
water leaking from water control board.
After turning off water to icemaker, defective control removed (two screws) and new unit installed.Worked perfectly.I was totally amazed when I ordered the part thursday afternoon and it arrived fridaY morning.Total time out of operation less than 24 hours.Wonderful results.
0 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Missy from Naples, FL
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Not making cubes
Wires in cutter grid were broken and wouldn't freeze/cut ice. Replaced with the new ice cutter grid that came completely assembled. Put it in with a screwdriver in less than 10 minutes. Ice cubes ready in 45 minutes. Repair guy told me it would be $455 for him to repair it. With shipping, mine was $133 and 10 minutes of my time. Well worth doing it myself.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Nashville, TN
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Leaking solenoid operated water value on ice maker.
Removal of old valve very easy and accessible, 2 screw/bolts for mounting, disconnect to electrical leads by hand, disconnect 2 plastic water lines with push/pull connectors and reverse order for installation. Total time-less than 5 minutes and basically no tools required expect pliers or nut drive to loosen screw/bolts. Just turn on and it was making ice
Was this instruction helpful to you?
Thank you for voting!
Customer:
harold from cleveland, TX
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alfred from Hot Springs, AR
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Water Was Leaking Into The Control Board
I removed the inspection cover, removed 2 screws holding the control valve,depressed the realease rings on the water lines,unpluged the 2 electrical connections and removed the bad valve. I re-installed the water lines into the new part, reconnected the electrical plugs,replaced the 2 screws in the new valve keeper and replaced the inspection cover. Everything I received from partselect fit perfectly. Thank you partselect, the ice machine works great. I sure was glad you were there. Thanks,, alfred harvey
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lonnie E. from Canton, MO
Parts Used:
WP4387938
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Failed to Run
Checked Overload Start Relay With Volt Ohm Meter&Replaced Them Easy And Simple Repair
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Fairport, NY
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Socket set
Wobble in fan made a ticking noise.
Pulled out the Fridge. Removed the plug. Removed the back panel screws with nut driver. Vacuumed the coils & fan area. Disconnected the fan cable. Used a socket and thumb ratchet to remove the 3 mounting screws from its sheet metal bracket. Slid the old fan assembly out. Assembled the new Fan blade onto the new motor shaft and attached the adapter cable to the fan connector. Slid the assembly into place and reattached with 3 screws using socket and thumb ratchet. Connected adapter cable to fridge harness and plugged in the power cord to test the fan. With it working Quietly and knowing the the problem was solved, the back panel was reattached.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Albuquerque, NM
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
condenser fan motor worn out and making noise.
Instructions were really clear and easy to follow. Hardest part of the job was moving the refrigerator away from wall after it was filled with holiday groceries.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Salem, WI
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Wrench set
The old condenser fan was rattling and driving everyone nutts.
I surfed partselect and read that a reader had a similar problem with a rattling fan. I then removed the back panel, after I had unplugged the unit, and was able to feel the slop in the fan shaft. I then watched the video of how to replace the fan and ordered the part soon after. The part arrived 3 days later! Easy to do. I was finished in 12 minutes and the fridge runs silently. The part of the job that took the longest was vaccuming the undercarriage. There was alot of dust! Couldn't have helped the efficiency on the fridge. Keep it clean.
Was this instruction helpful to you?
Thank you for voting!
Customer:
martin from grafton, WI
Parts Used:
WP2149705
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
non functioning light switch in fridge
This repair was super easy. there are only 5 screws to remove to get at the defective switch. 3 in the housing where the light bulbs are and 2 in the front trim piece where the cooling adjustment dials are. I never did unplug the fridge ,but probably should have although nothing bad happened. I removed all 5 screws using a 1/4" socket ( a nutdriver would work well also). there is also a small dia rod that comes down from the coolness adj. wheel that when you re-assemble goes though the middle of the wheel. The switch has only 2 wires that clip on with the push on flat type connectors. Very simple. I removed the wires and then the switch can be removed( it is only held in by 2 squeezable side clips). I put the new switch in and connected the wires , checked to see that the lights went on and off. which they did. then just put the screws back in.....done. also I would like to say that when I ordered my switch it came super fast. I ordered it online at 11:00am on a tuesday and it was on my doorstep in wisconsin by 10:00 am the next day...Thanks
Was this instruction helpful to you?
Thank you for voting!