Customer:
William from RALEIGH, NC
Parts Used:
W10124096
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Replacing Condenser Fan
I was anticipating that the fan would be facing the back of the refrigerator. It actually was perpendicular to the back. There was some difficulty removing the bolts of the fan. I persevered and was victorious.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Floyd from VIAN, OK
Parts Used:
WPW10548509
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Sensor quit working
Removed and replaced sensor
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from CHAMPAIGN, IL
Parts Used:
W10823511, W11179302
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
ice maker leaking water, and not making ice
Remove the cardboard back cover and the vertical metal strip, all the screws are the same on the back. Remove the front bottom cover, those screws are all the same but longer. The tubing is bad because they tucked it in on the side and it rubbed and wore a hole in it. Remove the tubing nut. You may notice that there is an insert in the tubing, but the new tubing has no insert because it is thicker walled and does not the insert because it is stronger. The nut and compression ring are one piece. Open the front door and pull the tube out of the metal plate to the left, and cut the tube off at the end to remove the metal ring, and to make it easier to pull it out. Pull the tube out from the back, but first carefully remove the sticky gray putty, and put it aside. You might also bend the copper line to the right a little if it is putting pressure on the tube at the top of the unit. Now pull the tubing out, and use it to make the new tube the proper length, You might also want to first tape the new tube to the old tube to fish it through. I did not. It was tricky fishing the tube in from the back of the unit to the resevoir. If you do it my way, then aim it to the right. I got it on the second try and felt lucky. Once you get the tube in there, put the metal ring back on the new tube, and press it into the metal plate to the right. You can feel the groove and hole in the metal plate. I think the metal ring goes under the plate, but honestly I don't think you need the ring on the new tube because it has a thicker wall and is stiffer, so it won't pop out. Make sure you put the putty back in once you have completely installed the tubing. I think this is important to keep the tubing from sweating and to help keep the ice bin cold, like insulation. Do not put the tubing back along the left side of the unit, or you will be replacing it again, but maybe not with the thicker walled tubing. When you are all done, check to make sure your sump pump works by pouring water into the ice tub, if it is plugged in and you do not hear the pump, or the water backs up, then your pump may be bad. I also pulled a piece of white plastic out of the clear tubing just above the pump and never did find where that came from, but it would have been from the ice bin. I then ran a cleaning cycle and the instructions say if there was water still in the resevoir, then do another cleaning. My resevoir was full, so I did another cleaning. IF YOUR RESEVOIR IS FULL, THEN YOU NEED A NEW UPPER PUMP! Mine is on order. Mine was full after both cleanings, and after trying to make ice, I realized what the problem was. It could be that it is very clogged, but they don't appear to be serviceable, and I never heard it try to run. I did hear the lower pump, compressor, and fan all run previously, so I hope that when the new pump is installed, the unit is not low on refrigerant or anything like that. Fingers crossed, and good luck.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from BLACKLICK, OH
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
loud griding noise
stopped the fan and noise stopped ordered fan motor and fan with interface cable. Using 1/4 inch nut driver to remove screws from motor bracket installed new motor and runs like new.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from BULLHEAD CITY, AZ
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Noisy condenser fan
I suggest following video supplied with order confirmation perfect fit
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from RICHMOND, VA
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Valve needed replacement - ice had become very thin
Just install the new valve by reversing the process of removing the old valve. Only possible nance is with the quick release hose fittings - the collar is pushed down to release the hose. Also, be sure to FULLY reinsert the hose in the new valve. Best to twist the hose a bit when inserting so it goes through the o-ring inside the valve. If not fully inserted, it will leak.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from NORMAN, OK
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Broken ice cutter grid
Unplugged the unit. Removed 2 screws to remove front cover to access the cutter grid.removed 2 screws to the cutter grid, unsnapped power connector and removed broken grid. Slid new grid in place, reconnected power connector, replaced screws, plugged in ice maker and slid back in place. Very easy!!!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
guadalupe from RIALTO, CA
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Motor sounded like a small little airplane under my fridge, very loud.
Unplugged the fridge first then took the bottom panel off with a 1/4 inch nut driver. Disconnected the wiring & used my ratchet to reach the 3 screws that held the motor. Took me longer to clean the bottom of the fridge then the installation.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Huntsville, AL
Parts Used:
W11566407, WPW10548509, W11566405
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
One of the circulation pumps was going bad and making a loud noise.
I replaced the two pumps, since both were the same design...figuring if one went bad then the other would soon go bad...and then I also replace the water level sensor. All had quick connect plugs. The time is just taking apart the various pieces, cleaning, installing the new pumps and sensor, then reassembling.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Sherwood, OR
Parts Used:
WP9872207S
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
door handle scratch
replaced handle
2 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frances from palm beach gardens, FL
Parts Used:
WP179051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
range handle fell off and screw got lost
It was worth the money for that little screw, since I didn't have to run all over trying to find the right one.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barton from Ringgold, GA
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
leaking water inlet valve
Received replacement valve ~ 3 days, easily replaced in less than 15min, works great
4 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lindey from Austin, TX
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freeze ruptured inlet valve
Simple to replace. Next fall I will be sure to drain the outdoor icemake and shut it down for the winter.
7 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
otis from frenchburg, KY
Parts Used:
WPW10217917
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
water leaking from water control board.
After turning off water to icemaker, defective control removed (two screws) and new unit installed.Worked perfectly.I was totally amazed when I ordered the part thursday afternoon and it arrived fridaY morning.Total time out of operation less than 24 hours.Wonderful results.
0 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alfred from Hot Springs, AR
Parts Used:
WPW10217917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Water Was Leaking Into The Control Board
I removed the inspection cover, removed 2 screws holding the control valve,depressed the realease rings on the water lines,unpluged the 2 electrical connections and removed the bad valve. I re-installed the water lines into the new part, reconnected the electrical plugs,replaced the 2 screws in the new valve keeper and replaced the inspection cover. Everything I received from partselect fit perfectly. Thank you partselect, the ice machine works great. I sure was glad you were there. Thanks,, alfred harvey
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the KUIC15NLTS2
61 - 75 of 159