Jason from CHAMPAIGN, IL
Parts Used:
W10823511, W11179302
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
ice maker leaking water, and not making ice
Remove the cardboard back cover and the vertical metal strip, all the screws are the same on the back. Remove the front bottom cover, those screws are all the same but longer. The tubing is bad because they tucked it in on the side and it rubbed and wore a hole in it. Remove the tubing nut. You may notice that there is an insert in the tubing, but the new tubing has no insert because it is thicker walled and does not the insert because it is stronger. The nut and compression ring are one piece. Open the front door and pull the tube out of the metal plate to the left, and cut the tube off at the end to remove the metal ring, and to make it easier to pull it out. Pull the tube out from the back, but first carefully remove the sticky gray putty, and put it aside. You might also bend the copper line to the right a little if it is putting pressure on the tube at the top of the unit. Now pull the tubing out, and use it to make the new tube the proper length, You might also want to first tape the new tube to the old tube to fish it through. I did not. It was tricky fishing the tube in from the back of the unit to the resevoir. If you do it my way, then aim it to the right. I got it on the second try and felt lucky. Once you get the tube in there, put the metal ring back on the new tube, and press it into the metal plate to the right. You can feel the groove and hole in the metal plate. I think the metal ring goes under the plate, but honestly I don't think you need the ring on the new tube because it has a thicker wall and is stiffer, so it won't pop out. Make sure you put the putty back in once you have completely installed the tubing. I think this is important to keep the tubing from sweating and to help keep the ice bin cold, like insulation. Do not put the tubing back along the left side of the unit, or you will be replacing it again, but maybe not with the thicker walled tubing. When you are all done, check to make sure your sump pump works by pouring water into the ice tub, if it is plugged in and you do not hear the pump, or the water backs up, then your pump may be bad. I also pulled a piece of white plastic out of the clear tubing just above the pump and never did find where that came from, but it would have been from the ice bin. I then ran a cleaning cycle and the instructions say if there was water still in the resevoir, then do another cleaning. My resevoir was full, so I did another cleaning. IF YOUR RESEVOIR IS FULL, THEN YOU NEED A NEW UPPER PUMP! Mine is on order. Mine was full after both cleanings, and after trying to make ice, I realized what the problem was. It could be that it is very clogged, but they don't appear to be serviceable, and I never heard it try to run. I did hear the lower pump, compressor, and fan all run previously, so I hope that when the new pump is installed, the unit is not low on refrigerant or anything like that. Fingers crossed, and good luck.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frances from palm beach gardens, FL
Parts Used:
WP179051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
range handle fell off and screw got lost
It was worth the money for that little screw, since I didn't have to run all over trying to find the right one.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
martin from grafton, WI
Parts Used:
WP2149705
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
non functioning light switch in fridge
This repair was super easy. there are only 5 screws to remove to get at the defective switch. 3 in the housing where the light bulbs are and 2 in the front trim piece where the cooling adjustment dials are. I never did unplug the fridge ,but probably should have although nothing bad happened. I removed all 5 screws using a 1/4" socket ( a nutdriver would work well also). there is also a small dia rod that comes down from the coolness adj. wheel that when you re-assemble goes though the middle of the wheel. The switch has only 2 wires that clip on with the push on flat type connectors. Very simple. I removed the wires and then the switch can be removed( it is only held in by 2 squeezable side clips). I put the new switch in and connected the wires , checked to see that the lights went on and off. which they did. then just put the screws back in.....done. also I would like to say that when I ordered my switch it came super fast. I ordered it online at 11:00am on a tuesday and it was on my doorstep in wisconsin by 10:00 am the next day...Thanks
Was this instruction helpful to you?
Thank you for voting!
Customer:
harold from cleveland, TX
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Las Vegas, NV
Parts Used:
WP2217220
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
No water running across the evaporate plate
Since no ice was forming on the evaporator plate, I first checked to see if I was getting water. Water to reservoir was fine, but it was not moving from the reservoir. Pretty logical that something was wrong with the pump. I pulled pump out. It was locked up, with a significant amount of calcium buildup. Replaced it and all works fine. Great ice again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Clanton, AL
Parts Used:
W10881366
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Inlet water valve restricted with debree.
Open appliance door. Removed access plate at lower front (two screws). Removed two screws holding valve in place. Depressed water line retainers and removed water lines from valve. Inserted water lines in replacement valve, remounted valve, reinstalled access plate. Tested operation. (I did install a water filter during the repair to prevent reoccurrence.)
Was this instruction helpful to you?
Thank you for voting!
Customer:
doug from atlanta, GA
Parts Used:
WP2217220
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Water was not circulating onto freezing plate
Simple, remove water reservoir (2 screws). Remove pump cover (1 screw). Remove 2 screws on bracket holding pump and unplug pump. My wiring was somewhat corroded and it took a bit of pulling to unplug. When you replace with new motor make sure to snap in new plug snug or it will not start up. Reassemble and away you go.Making ice no problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Fairport, NY
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Socket set
Wobble in fan made a ticking noise.
Pulled out the Fridge. Removed the plug. Removed the back panel screws with nut driver. Vacuumed the coils & fan area. Disconnected the fan cable. Used a socket and thumb ratchet to remove the 3 mounting screws from its sheet metal bracket. Slid the old fan assembly out. Assembled the new Fan blade onto the new motor shaft and attached the adapter cable to the fan connector. Slid the assembly into place and reattached with 3 screws using socket and thumb ratchet. Connected adapter cable to fridge harness and plugged in the power cord to test the fan. With it working Quietly and knowing the the problem was solved, the back panel was reattached.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ALAN from KENNETT, MO
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
macnine was producing ice but would not cut into cubes
remove the front cover by removing two screws. then remove two screws with a nut driver on each side. unplug the wireing harness from the top of the unit (may need pliers for this) the pull the unit out. then slide the new unit in, connect the wireing harness, install two side screws, and install the front cover and wham you will have ice in about 30 minutes. thanks parts select. you were very easy to deal with
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Metairie, LA
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Wire in ice cutter assembly had broken
Removed old assembly by disconnecting 2 wiring harness connections and loosening 2 screws with nutdriver. Installed new assembly using same process. Had ice in about an hour. Very easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Saint Augustine, FL
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Loud fan motor
Removed lower plate on back of refridgerator and changed out fan. The video was great and made the repair a snap. Fan is quiet and no more overheating refridgerator.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Lake tapps, WA
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Loud condenser fan
Pretty much followed the how to video. Biggest pain was removing the screws to the bracket that houses the motor.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Albuquerque, NM
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
condenser fan motor worn out and making noise.
Instructions were really clear and easy to follow. Hardest part of the job was moving the refrigerator away from wall after it was filled with holiday groceries.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Coon Rapids, MN
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Very noisy operation
Removed and replaced the condenser motor fan kit. This was a very easy tear down and replacement of a bad component. Removed 4 screws to remove the bracket holding the fan motor kit pulled it out and replaced with the new unit (4 screws supplied) plgged in adapter cord (supplied) and re-installed took about 10 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Salem, WI
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Wrench set
The old condenser fan was rattling and driving everyone nutts.
I surfed partselect and read that a reader had a similar problem with a rattling fan. I then removed the back panel, after I had unplugged the unit, and was able to feel the slop in the fan shaft. I then watched the video of how to replace the fan and ordered the part soon after. The part arrived 3 days later! Easy to do. I was finished in 12 minutes and the fridge runs silently. The part of the job that took the longest was vaccuming the undercarriage. There was alot of dust! Couldn't have helped the efficiency on the fridge. Keep it clean.
Was this instruction helpful to you?
Thank you for voting!