- Customer:
- doug from atlanta, GA
- Parts Used:
- WP2217220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Water was not circulating onto freezing plate
Simple, remove water reservoir (2 screws). Remove pump cover (1 screw). Remove 2 screws on bracket holding pump and unplug pump. My wiring was somewhat corroded and it took a bit of pulling to unplug. When you replace with new motor make sure to snap in new plug snug or it will not start up. Reassemble and away you go.Making ice no problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- martin from grafton, WI
- Parts Used:
- WP2149705
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
non functioning light switch in fridge
This repair was super easy. there are only 5 screws to remove to get at the defective switch. 3 in the housing where the light bulbs are and 2 in the front trim piece where the cooling adjustment dials are. I never did unplug the fridge ,but probably should have although nothing bad happened. I removed all 5 screws using a 1/4" socket ( a nutdriver would work well also). there is also a small dia rod that comes down from the coolness adj. wheel that when you re-assemble goes though the middle of the wheel. The switch has only 2 wires that clip on with the push on flat type connectors. Very simple. I removed the wires and then the switch can be removed( it is only held in by 2 squeezable side clips). I put the new switch in and connected the wires , checked to see that the lights went on and off. which they did. then just put the screws back in.....done. also I would like to say that when I ordered my switch it came super fast. I ordered it online at 11:00am on a tuesday and it was on my doorstep in wisconsin by 10:00 am the next day...Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Waterford, WI
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Failed cooling fan
The repair was simple. Unplug the refrigerator, unplug the power connector from the fan and remove 3 screws. I removed the fan blade clip with the pliers and cleaned it off. Reversed the process, cleaned all the dust out with my shop vac and all works perfectly now. It took longer to pull the fridge out of it's normal position than to perform the repair. Every day it continues to work is one more day I don't spend $2000 or more on a replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BRUCE from KRUM, TX
- Parts Used:
- W10822259
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Unit Running Hot
Insalled fan motor,problem went away. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from Mount Juliet, TN
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Condensor fan stopped working, refrigerator got hot.
1. Unplug the refrigerator. 2. Remove the back cover at the bottom of the refrigerator. 3. Remove the two screws holding the vertical black bracket the fan is mounted to. This allows the bracket to move easily. The bracket does not have to be removed. 4. Removed the four screws holding the fan bracket to the vertical bracket. 5. Unplug the power connector from the fan motor. 6. Remove the entire fan bracket assembly from the refrigerator. 7. Remove the 4 screws holding the fan motor to the fan motor bracket and unmount the fan motor. 8. Remove the nut holding the fan blade to the fan motor and remove the fan blade. 9. Reverse the process, mounting the fan blade to the new motor, screw the motor to the bracket, screw the bracket to the vertical bracket, screw the vertical bracket to the refrigerator and plug the power connector back into the motor. I did not have to use any of the extra mounting hardware or electrical hardware provided with the kit. It might be a good idea to purchase a new fan blade with the motor kit, the fan blade can get pretty grungy. I cleaned the fan blade with some degreaser before remounting it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy L from Middlebourne, WV
- Parts Used:
- WP2149705
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Light switch inoperative
Remove inside door trim plate. Then removed three screws that held in the light assembly. The only difficult thing was reconnecting the temperature adjustment rod. After replacing this rod you must slide the temperature control slide to midway and this hold the rod in place while reinstalling the light assembly. If I were to do it again it would probably take me half as long.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Hollister, CA
- Parts Used:
- W10822259
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
Noisy Motor
Pulled refrigerator away fom wall. Removed cardboard cover at back bottom to reveal fan motor.The space available to remove the motor from the bracket is very limited, so smaller hands will be a plus! Tried to get a nut wrench on motor but there was hardly enough room. Finally was able to use a socket set to remove bolts. I would suggest you spray a solvent on the motor mount bolts and seat them in the new motor first. It was near to impossible to get them started in the mount, without seating them first. The electrical clip that connects to the motor fit on the new motor, so I did not have to splice any wiring. This made the job a little easier. Finally, replaced cardboard cover and moved refrigerator back against the wall. .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Cardiff, CA
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refridgerator would not stay cool, eventually over burdened the freezer.
Over a period of weeks I watched my fridge grand to a halt. It was...saddening. I felt helpless, there was nothing I could do and I wasn't prepared to pull in a repairman. Upon it's departure from being affective (broke) I made up my mind to purchase a new one!! Flash-forward five minutes n the internet ...motivator by high costs, I altered my thinking and visited You Tube for a fix-it video. After a quick search I came across a clip that took me to the heart of the problem. It was THAT easy. Wow!! I followed the instructions and quickly learned the failure had to do with a small, light weight fan that's role was to pull heat from the condenser--it had ceased to work. While waiting for the part, I let a small fan blow on the condenser to dissipate the heat. The fridge roared to life!! Like a charm!! When the new fan body arrived I placed the blade from the old fan on it and installed it (the fan did not come with bolts and the holes were not threaded) using sheet metal screws. It immediately came started performing again and has been doing a superb job ever since. I easily saved $800 in costs going this route!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- harold from cleveland, TX
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Heather from Benbrook, TX
- Parts Used:
- W10801996
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water reservoir not filling up...
I undid the bottom screws off the bottom front of the ice machine under the door... Knowing the water valve was at the front it made it super easy to get to and I didn't have to pull the machine out from under the counter etc. Turned off the water supply at the wall, disconnected that line at the valve, removed the line from the valve to the water reservoir. Unscrewed two screws that held it to the machine wall and put the new valve in, reconnected both lines and voila! Done! Running like its never run before. I filled up that reservoir for weeks by hand many times a day so the satisfaction is huge to have saved a fortune by fixing it myself! And I'm female which makes it even more satisfying. A monkey could put this part in. Anything a man can fix, I can fix too! Ha!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Denham Springs, LA
- Parts Used:
- W10801996
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water reservoir was not filling up all the way.
This causes more than one problem. When the system does not get enough water it makes thin ice. When the ice is thin it does not have the mass to slide down on to the cutting grid and stops about half way down. When the pump starts running again, the water hits the ice sheet that did not make it to the grid and water goes all over the place thus emptying the reservoir then it makes no ice. Water was entering very slowly into the reservoir with very little pressure. Changed the water valve and now pressure is higher and fills the reservoir completely enough to flush the reservoir as it is supposed to do. Works great and makes plenty of ice now. Just take the front bottom cover off by the 4 screws holding it on and look to the left and you will see the water valve. Get the vacuum cleaner and clean the condenser coils while you have it open.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Las Vegas, NV
- Parts Used:
- WP2217220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
No water running across the evaporate plate
Since no ice was forming on the evaporator plate, I first checked to see if I was getting water. Water to reservoir was fine, but it was not moving from the reservoir. Pretty logical that something was wrong with the pump. I pulled pump out. It was locked up, with a significant amount of calcium buildup. Replaced it and all works fine. Great ice again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Metairie, LA
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Wire in ice cutter assembly had broken
Removed old assembly by disconnecting 2 wiring harness connections and loosening 2 screws with nutdriver. Installed new assembly using same process. Had ice in about an hour. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Drew from Birmingham, AL
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Claudia from Watauga, TX
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Condensor fan motor not working
Removed the back lower cover, behind the fridge. Uncliped the wiring. Removed the motor, (3 Screws).I did check the new motor before removal of the old one, to verify the older motor was the problem. After removal of the fan & motor. Removed the fan and placed it on the new motor, three screws later, plugged up the wiring, (I didn't changout the wiring, and the Refrigerator is good as new.
Was this instruction helpful to you?
Thank you for voting!