ice maker leaking water, and not making ice
Remove the cardboard back cover and the vertical metal strip, all the screws are the same on the back. Remove the front bottom cover, those screws are all the same but longer. The tubing is bad because they tucked it in on the side and it rubbed and wore a hole in it. Remove the tubing nut. You may notice that there is an insert in the tubing, but the new tubing has no insert because it is thicker walled and does not the insert because it is stronger. The nut and compression ring are one piece. Open the front door and pull the tube out of the metal plate to the left, and cut the tube off at the end to remove the metal ring, and to make it easier to pull it out. Pull the tube out from the back, but first carefully remove the sticky gray putty, and put it aside. You might also bend the copper line to the right a little if it is putting pressure on the tube at the top of the unit. Now pull the tubing out, and use it to make the new tube the proper length, You might also want to first tape the new tube to the old tube to fish it through. I did not. It was tricky fishing the tube in from the back of the unit to the resevoir. If you do it my way, then aim it to the right. I got it on the second try and felt lucky. Once you get the tube in there, put the metal ring back on the new tube, and press it into the metal plate to the right. You can feel the groove and hole in the metal plate. I think the metal ring goes under the plate, but honestly I don't think you need the ring on the new tube because it has a thicker wall and is stiffer, so it won't pop out. Make sure you put the putty back in once you have completely installed the tubing. I think this is important to keep the tubing from sweating and to help keep the ice bin cold, like insulation. Do not put the tubing back along the left side of the unit, or you will be replacing it again, but maybe not with the thicker walled tubing. When you are all done, check to make sure your sump pump works by pouring water into the ice tub, if it is plugged in and you do not hear the pump, or the water backs up, then your pump may be bad. I also pulled a piece of white plastic out of the clear tubing just above the pump and never did find where that came from, but it would have been from the ice bin. I then ran a cleaning cycle and the instructions say if there was water still in the resevoir, then do another cleaning. My resevoir was full, so I did another cleaning. IF YOUR RESEVOIR IS FULL, THEN YOU NEED A NEW UPPER PUMP! Mine is on order. Mine was full after both cleanings, and after trying to make ice, I realized what the problem was. It could be that it is very clogged, but they don't appear to be serviceable, and I never heard it try to run. I did hear the lower pump, compressor, and fan all run previously, so I hope that when the new pump is installed, the unit is not low on refrigerant or anything like that. Fingers crossed, and good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Hollister, CA
- Parts Used:
- W10822259
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
Noisy Motor
Pulled refrigerator away fom wall. Removed cardboard cover at back bottom to reveal fan motor.The space available to remove the motor from the bracket is very limited, so smaller hands will be a plus! Tried to get a nut wrench on motor but there was hardly enough room. Finally was able to use a socket set to remove bolts. I would suggest you spray a solvent on the motor mount bolts and seat them in the new motor first. It was near to impossible to get them started in the mount, without seating them first. The electrical clip that connects to the motor fit on the new motor, so I did not have to splice any wiring. This made the job a little easier. Finally, replaced cardboard cover and moved refrigerator back against the wall. .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andrew from Mission Viejo, CA
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Fan motor making awful noise, not turning very fast
Fan was barely rotating. So unplugged, removed back cover, removed fan and motor from frame work. Removed fan blade from motor shaft. Spun motor shaft which seemed fine. Pryed off back cover of motor to find a large but dry felt washer and a helical capillery slot formed into the motor shaft for carring oil from felt washer to the bearings. Added 30 wt motor oil and some 3in1 oil to felt and reassembled motor, fan and frame work. Plugged in power chord after getting rid of dust and dog hear on coils and is working like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy L from Middlebourne, WV
- Parts Used:
- WP2149705
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Light switch inoperative
Remove inside door trim plate. Then removed three screws that held in the light assembly. The only difficult thing was reconnecting the temperature adjustment rod. After replacing this rod you must slide the temperature control slide to midway and this hold the rod in place while reinstalling the light assembly. If I were to do it again it would probably take me half as long.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Friendswood, TX
- Parts Used:
- WP2217220
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Hard water deposits salted pump motor
Disconnect water line and power cord, Remove scoop holder, water reservoir and shield around pump to access pump, removed hose connected to pump then removed pump (3- 1/4" hex screws) and disconnected wire harness and 1/4" plastic water line attached to pump bracket, reverse process
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Norman, OK
- Parts Used:
- W10822259
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set, Wrench set
Fan motor making noise then failed. Ice maker stopped making ice
Once I determined easier access to the fan motor, I removed the three fan motor screws that held the motor on place. After removing the motor I remove the fan blade assembly held by one nut and reattached to the new motor. I then reattached the new motor with 3 new screws which were provide and reattached the power cord with the cord clip and began reassembling the icemaker housing, then moved the unit back in place which was installed under counter. I could do this repair in less than 45 minutes now that I have done it once. I saved several hundred $ from the original estimate and the parts were delivered in 2 days after I ordered online. This is definitely a DIY project!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Cardiff, CA
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refridgerator would not stay cool, eventually over burdened the freezer.
Over a period of weeks I watched my fridge grand to a halt. It was...saddening. I felt helpless, there was nothing I could do and I wasn't prepared to pull in a repairman. Upon it's departure from being affective (broke) I made up my mind to purchase a new one!! Flash-forward five minutes n the internet ...motivator by high costs, I altered my thinking and visited You Tube for a fix-it video. After a quick search I came across a clip that took me to the heart of the problem. It was THAT easy. Wow!! I followed the instructions and quickly learned the failure had to do with a small, light weight fan that's role was to pull heat from the condenser--it had ceased to work. While waiting for the part, I let a small fan blow on the condenser to dissipate the heat. The fridge roared to life!! Like a charm!! When the new fan body arrived I placed the blade from the old fan on it and installed it (the fan did not come with bolts and the holes were not threaded) using sheet metal screws. It immediately came started performing again and has been doing a superb job ever since. I easily saved $800 in costs going this route!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BRUCE from KRUM, TX
- Parts Used:
- W10822259
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Unit Running Hot
Insalled fan motor,problem went away. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from Mount Juliet, TN
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Condensor fan stopped working, refrigerator got hot.
1. Unplug the refrigerator. 2. Remove the back cover at the bottom of the refrigerator. 3. Remove the two screws holding the vertical black bracket the fan is mounted to. This allows the bracket to move easily. The bracket does not have to be removed. 4. Removed the four screws holding the fan bracket to the vertical bracket. 5. Unplug the power connector from the fan motor. 6. Remove the entire fan bracket assembly from the refrigerator. 7. Remove the 4 screws holding the fan motor to the fan motor bracket and unmount the fan motor. 8. Remove the nut holding the fan blade to the fan motor and remove the fan blade. 9. Reverse the process, mounting the fan blade to the new motor, screw the motor to the bracket, screw the bracket to the vertical bracket, screw the vertical bracket to the refrigerator and plug the power connector back into the motor. I did not have to use any of the extra mounting hardware or electrical hardware provided with the kit. It might be a good idea to purchase a new fan blade with the motor kit, the fan blade can get pretty grungy. I cleaned the fan blade with some degreaser before remounting it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Claudia from Watauga, TX
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Condensor fan motor not working
Removed the back lower cover, behind the fridge. Uncliped the wiring. Removed the motor, (3 Screws).I did check the new motor before removal of the old one, to verify the older motor was the problem. After removal of the fan & motor. Removed the fan and placed it on the new motor, three screws later, plugged up the wiring, (I didn't changout the wiring, and the Refrigerator is good as new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from Warsaw, MO
- Parts Used:
- WP2149705
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Recent move and movers broke the light switch on refrigerator side.
Unplugged the refrigerator then removed two vertical screws on the very back back of the control panel (the ones with the washers). Do not remove the four other vertical screws in the panel. The front plastic plate on control panel snaps off and there are two horizontal screws under the plate. Remove them and the control panel will drop down allowing access to the light switch. Unplug the two wires (one black and one white) from the old switch. Discard the old switch, snap the new one into place and reconnect the two wires. Snap the front plastic plate back into place, plug in the refrigerator and you are done! Problem solved with a new $16.00 switch and saved at least $75.00 or more from an appliance repair call. Thanks Part Select!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- harold from cleveland, TX
- Parts Used:
- WP2313637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Heather from Benbrook, TX
- Parts Used:
- W10801996
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water reservoir not filling up...
I undid the bottom screws off the bottom front of the ice machine under the door... Knowing the water valve was at the front it made it super easy to get to and I didn't have to pull the machine out from under the counter etc. Turned off the water supply at the wall, disconnected that line at the valve, removed the line from the valve to the water reservoir. Unscrewed two screws that held it to the machine wall and put the new valve in, reconnected both lines and voila! Done! Running like its never run before. I filled up that reservoir for weeks by hand many times a day so the satisfaction is huge to have saved a fortune by fixing it myself! And I'm female which makes it even more satisfying. A monkey could put this part in. Anything a man can fix, I can fix too! Ha!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Denham Springs, LA
- Parts Used:
- W10801996
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water reservoir was not filling up all the way.
This causes more than one problem. When the system does not get enough water it makes thin ice. When the ice is thin it does not have the mass to slide down on to the cutting grid and stops about half way down. When the pump starts running again, the water hits the ice sheet that did not make it to the grid and water goes all over the place thus emptying the reservoir then it makes no ice. Water was entering very slowly into the reservoir with very little pressure. Changed the water valve and now pressure is higher and fills the reservoir completely enough to flush the reservoir as it is supposed to do. Works great and makes plenty of ice now. Just take the front bottom cover off by the 4 screws holding it on and look to the left and you will see the water valve. Get the vacuum cleaner and clean the condenser coils while you have it open.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Las Vegas, NV
- Parts Used:
- WP2217220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
No water running across the evaporate plate
Since no ice was forming on the evaporator plate, I first checked to see if I was getting water. Water to reservoir was fine, but it was not moving from the reservoir. Pretty logical that something was wrong with the pump. I pulled pump out. It was locked up, with a significant amount of calcium buildup. Replaced it and all works fine. Great ice again.
Was this instruction helpful to you?