Models
>
MHU45
MHU45 Mr Heater Heater
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for MHU45
Viewing 1 of 1Keep searches simple, eg. "belt" or "pump".
In Stock
$85.55
This is a genuine OEM replacement part sourced directly from the manufacturer, and is compatible with certain models of compact heaters manufactured by Mr. Heater and Heat Star. For full compatibility...
Special Order
In Stock
In Stock
In Stock
On Order
On Order
Special Order
In Stock
Special Order
In Stock
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Paul
January 4, 2022
Getting 3 flashes on my board saying it's the pressure switch, wondering if there is a way to check it to make sure that is the problem? Goes thru purging but never tries to ignite, and then shut down completely.
For model number MHU45
Hi Paul,
Thank you for your question. To verify if the issue is with the pressure switch, check the fan in the combustion chamber to see if the air flow is being restricted. If the air flow is fine, check the tube between the pressure switch and the induced draft motor to make sure that it is connected correctly and that there are no obstructions preventing it from working correctly. If it is fine, then you will need to replace the pressure switch. We hope this helps! If you have any questions, please let us know.
Was this helpful?
Thank you for voting!
Related Parts:
TOM
November 18, 2022
Getting 2 flashes on the control board and noticed the igniter did not light, replaced the igniter with no change. Could it be the spade fuse on the board is blown, or do i just need to replace the entire board?Thank you,
tom
For model number MHU45
Hi Tom, thank you for reaching out. Before replacing the control board, part number FIX10369260, we would recommend checking the following parts: Electrode Sensor, part number FIX12031770, Electrode Igniter, part number FIX12094716, and Pressure Switch, part number FIX10369240. We hope this helps! If you need help placing an order, customer service is open 7 days a week. Thanks again for your great question.
Was this helpful?