Models > 01919 > Instructions

01919 Generator - Instructions

Jump to:

All Instructions for the 01919
1 - 3 of 3
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
James from PICAYUNE, MS
Parts Used:
192980GS
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Dry rotted rubber
Put some dish soap on the rubber, push into the tank hole, slip 1x2 into the handle of the tank and over the new part and pry down pushing it into the hole. Took about 2 minutes.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from RADFORD, VA
Parts Used:
192980GS
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
old valve dripped gas when opened on cold sub zero day
old valve easily pulled out with screwdriver and pliers

install difficult due to 40 degree cold temp and bushing didn't want to squeeze into fuel tank hole

install required lots of liquid soap on bushing, which popped into place by using upward prying pressure from 3"X24" plywood braced into under-shelf of gas tank

used same technique to insert valve upward into bushing

works great!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from LEES SUMMIT, MO
Parts Used:
192980GS
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
major gas leak on my generator
popped out the old-----the bushing failed. replaced as per the included instructions
5 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 01919
1 - 3 of 3