Mike from Kilgore, TX
Parts Used:
5304464438, 216008900
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
compressor wouldn't start
I used a pick to remove the lugs from the old starter. Clicked them right in the new one and it went to woking!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Brandon, FL
Parts Used:
5304518034, 216254500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Unit Would Not Freeze And The Coils Would Ice Over And There Would Be Little Airflow From The Top Fan
Took interior panel off and uncliped yhe termination switch and cliped the new one on the coil and connected the two wires very simple. The defrost timer was located in the rear of the unit on the right side at the bottom. Removed the 2 screws holding the bracket unpluged the timer and removed the timer. The new timer allready had a bracket so just plug in and install the 2 screws. Pluged the unit in and worked great make sure that the freezer is unpluged before changing any part
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edwin from Littleton, CO
Parts Used:
5303925377
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The tabs on the shelf end broke off.
Removed the broken shelf ends and installed the new ones. Then installed the assembly on the freezer door. Trick was to put the long end of the tab in first followed by the short end. The up end was reversed on the opposite shelf end.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Macomb, MI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from Woodstock, GA
Parts Used:
5304442620
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Fan in freezer quit
This was an easy job. First remove the ice maker, if you have one. Mine was mounted with just two screws. Loosen these screws, unplug the power cord at the connector and then lift the ice maker off. Remove the light bulb cover and the light bulb, just so you dont break it. Remove two hex screws and the back cover can be removed. My fan was mounted in the middle of a bracket retained between two rubber bushingings. Just push the fan blad of the shaft and pull the motoer out. Dissonect the power cord at the connector. My moter was differant than the replacement on the mounting so with the removial of the two screws on the motor I was able to exchange the upper and lower cast motoer housings. Reverse the assembly process and you good. Mine is running great.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the MFU16F3BW0