- Customer:
- Walter from Vero Beach, FL
- Parts Used:
- 6600JB3007E, 3550JJ1070B, 3110JJ1014A
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Lights Stayed on Melted Light cover
Replaces door switches - removed screw from door hinge cover, lifted cover and removed switch. Plugged in new switch and reversed process. Removed screws from light bracket. Attached new frame to slots in roof and used screws to attach. Clipped on light cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sarah from Elk Grove, CA
- Parts Used:
- 4932JA3002A
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers
Each time we've had to move we have to remove the doors from the fridge to get it thru the front door.since water and ice run thru the freezer door there are 2 tubes that connect at the bottom of the freezer door that aren't meant to be separated very often if ever.it's easier to cut the tubing on b
With alot of elbow grease and a pair of pliars we managed to get the old connector off wo cuttig the tubing as the tubing was getting to short from being cut once to many times & there was no more play in the length.Original connector was a different color and shapped slightly different than the new one so was a bit concerned that I had ordered the wrong part but it went one very easily & did not leak. We even managed to remove it again just to see if it was possible wo cutting again. it came off with no trouble.I would say the replacement part was a better fit than the original simply because we could remove it easily wo having to cut the tube!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Troutdale, OR
- Parts Used:
- 6600JB3007E, 3550JJ1070B, 3110JJ1014A
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the lights inside the frig weren't shutting off
the lights melted the lamp case and cover. I determined it was the switch ,but there was 2 of them . I replaced both . I used a screw driver to pry the covers off the switches which are on the top of the unit .Then I press the tabs on the switch and pulled it out. Slip the wire connect off. slip the wire connect on new switch press it in till the tabs snap in ,put covers back on. the lamp base and cover had two screws holding them, pull the screws slip the old melted base and cover. snap the new base and cover in and put the screws in done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Bridge City, TX
- Parts Used:
- AEQ36756901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
icemaker quit working
My husband took out the ice maker. We ordered the part. He looked on YouTube for instructions. Including looking up instructions, I think it took him way less than an hour.
Was this instruction helpful to you?
Thank you for voting!