79577199600 Kenmore Freezer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Cedric from Milwaukee, WI
- Parts Used:
- AAP73871501
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken door
Simple replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pat from West Bend, WI
- Parts Used:
- MDS64172918
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The gasket on our bottom drawer freezer was torn
Simply used a flat head screwdriver to get the first few inches of the gasket out of its track and after that just pulled it by hand. New gasket slipped over the door, lined up the corner and pressed into in the track. Checked to see that it was snug all over and we were done. 5 minutes at the very most. Never would have noticed this. Took all the bins out of the freezer to give it a good cleaning and noticed the torn piece hanging. Our refrigerator runs much less often. Expect to see a difference in our electric bill!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter K from Newport Richie, FL
- Parts Used:
- 3391JJ2014A
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
vegetable tray assembly fine.
I need the slide rails right and left for the center of the trays.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Bay Shore, NY
- Parts Used:
- EAG62831801
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Interior Light Would Not Turn Off
Tape off the light button so door alarm does not go off. Take off the clear light shield and remove the light bulbs. Be careful, bulbs may still be HOT!! With Phillips head screw driver unscrew the light plate assy. Drop it down in a comfortable position. Disconnect the connector, unscrew the thermal sensor and remove light assy. Install new light assy into light plate assy. There is no thermal senor in the new assy. Snap light plate assy back into place and install the two screws previously taken out. Install bulbs and clear cover. Remove tape from light door switches and you are done. Lights should go on and off when door buttons are pushed in and out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Reginald A. Green from Pelham, AL
- Parts Used:
- 4430JJ2004B, 4430JJ2004A
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Plastic door latch/ cam shaft broke on left side door
Removed white plastic trim and installed new latch / cam shaft
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RONALD from LAKE WALES, FL
- Parts Used:
- 4838JA2002A
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
door mounted cold water tank was leaking at seam of polyethylene tank.
The part labeled as water tank was not pictured on web site, and when it arrived it was a large coil of plastic tubing wire-tied in an oval shape,not a blown p/e tank as original.The oval of tubing would not fit into the door compartment, because of the bulk of the actuating solenoid. No instructions were included. It was necessary to hacksaw the steel solenoid mounting bracket off the solenoid, then contort the solenoid into the compartment to get all parts inside the cover. new connectors had to be purchased, because the the tank/tubing coil was 1/4" od, while the original tank had 5/16"od connections.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Troutdale, OR
- Parts Used:
- 6600JB3007E, 3550JJ1070B, 3110JJ1014A
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the lights inside the frig weren't shutting off
the lights melted the lamp case and cover. I determined it was the switch ,but there was 2 of them . I replaced both . I used a screw driver to pry the covers off the switches which are on the top of the unit .Then I press the tabs on the switch and pulled it out. Slip the wire connect off. slip the wire connect on new switch press it in till the tabs snap in ,put covers back on. the lamp base and cover had two screws holding them, pull the screws slip the old melted base and cover. snap the new base and cover in and put the screws in done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- G.J. from WHITE BIRD, ID
- Parts Used:
- 6600JB3007E, 3550JJ1070B, 3110JJ1014A
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Lights in upper refrigerator would not turn off with doors closed
replaced melted light covers, replaced switches, and found another problem with power circuit board relay, on order now!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter from Vero Beach, FL
- Parts Used:
- 6600JB3007E, 3550JJ1070B, 3110JJ1014A
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Lights Stayed on Melted Light cover
Replaces door switches - removed screw from door hinge cover, lifted cover and removed switch. Plugged in new switch and reversed process. Removed screws from light bracket. Attached new frame to slots in roof and used screws to attach. Clipped on light cover.
Was this instruction helpful to you?
Thank you for voting!