106724242 Kenmore Freezer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Lee from Arvada, CO
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
noisey circulating fan in the freezer
Emptied the freezer. Removed the back panel. (six screws)Removed the fan cover.(4 screws) Unplugged the power. Unplugged three wires from the motor. (hot-neutral-ground)Removed the fan. (2 screws) Installed the new fan and centered for clearance. Reversed the prior instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Norwich, CT
- Parts Used:
- W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Refrigerator was freezing everything
First of all the part was not located in the section of the refrigerator that was shown in the video. I wasted a lot of time taking that section apart only to find that the part wasn't there. After some investigation I finally located the defective part. It was behind a piece of sheet metal that had to be bent out of the way to unscrew the part. If I hadn't bent it out of the way, it would have been a major disassembly to remove the sheet metal. Once removed, the installation of the new part was fairly simple. The only confusing thing about the installation was determinig which of the prongs on the part that the internal wire to the new part was to be attached. There were 3 options given and the instructions were not very clear as to which one I should use. Apparently I guessed correctly because the refrigerator seems to be functioning perfectly since the repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glenn from Capitol Heights, MD
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice on the botton of top freezer
I just simply eliminated the ice buildup with hot water and a knife. But I still have the Defrost Timer Kit for future use.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Austin, TX
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer not cooling. Temperature rising.
One day the ice cream in the freezer seemed mushy, but the ice was still frozen. There was not water in the ice bin. However, the problem resolved itself. This suggested that the defrost timer had become stuck for an extended time, but then continued to run. The fact that the freezer went back to frozen, implies that all the components of the cooling loop (compressor, condenser & fan, evaporator & fan) were fine. It was possible that the problem was caused by a bad defrost (?evaporator?) thermostat but everything I saw on line suggested that the defrost timer is the culprit about 40 - 50% of the time. Anyway, I followed the instructions in the on-line video at this site for replacing the defrost timer and it was easy. It would have only taken 15 minutes, but I spent a while reading the defrost timer instructions and hunting down a schematic for my refrigerator, to determine which pin the loose wire should go on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Hobe Sound, FL
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
See below
The defrost timer that I ordered form you did the trick. My fridge was
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Brooklyn, NY
- Parts Used:
- 4387478
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Protective cover for bulb had melted
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent items in the fridge from being able to touch. Bad solution.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Ledyard, CT
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Repalce evaporator fan
The evaporator fan is located in the freezer behind the back wall. If you have the ice maker remove it first then remove the screws on the top of the panel. You will notice the side brackets for the top shelf will make it hard to remve the panal but by slitly binding the center the panal came right out. The fan is held in a bracke tha comes right out. The wire unplu right from the fan so do not try to unplg the seal plug to the left side. Swap the fan with the new one useing the new rubber monts re-connect the wires and reasymble. Put the bottom of the back panal in first then work each side in past the shelf bracket binding the center slightly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eliseo from Pleasanton, TX
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
no problems at at all
removed rear wall panel took off old fan motor disconnected motor. Installed new grommets re-installed motor inserted new fan. Didn't have to trim fan re-connected wires and rear panel and reconnected power. no problems...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Sierra Vista, AZ
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
rReally Noisy Fan
1. Unplug Refrigerator 2. Remove inside back freezer panel. (4 Screws) 3. Remove Duct Cover (3 Screws). 4. Cut electrical connections to fan. 5. Remove Old Fan motor (2 hex screws. 6. Install ground wire (was not one there previously). 7. Put slide-on electrical connectors on remaining 2 motor wires. (Were not any on original unit.) 8. Replace Fan Motor (Don't forget the rubber vibration pads) 9. Reconnect electrical wires. 10. Press on plastic fan blade. 11. Plug in refrigerator to test install. It works. 12 Unplug refrigerator and replace ducting and back panel to freezer. Plug it back in. Voila, Quiet again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Grant from Alexandria, VA
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Cottsge Grove, WI
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Loud noise from freezer when running
Pulled the electric plug! Removed the freezer shelf and the rear shelf supports by pulling straight up. Swung rear panel out of the way after taking out the two phillips head screws at the top. Removed the plastic deflector grill to which the motor is attached with a nut driver. Removed motor from grill and disconnected wire prongs (pull off). Attach new motor. Only issue - the ground prong has been moved to the front of the motor so the wire just reaches and has to be gently bent back so the fan blade clears it. Reattach deflector grill. Push on fan blade, but not too far to hit wire. Reassemble the rest in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from buchanan, TN
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Evaporator Would Freeze Up And The Food Section Could'nt Cool
I just followed the enclosed instructions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Delano, MN
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water was running into refrig from freezer and ice cream was soft
We wasted time looking for the electrical schematic on our refrigerator (the first step in the instructions). By skipping that and reading further in the instructions, the type of cooling that the refrigerator has can easily be determined by the colors of the wires that go to the defrost timer. You need to know this to set up the timer properly for your specific refrigerator. Had I just started there, the entire repair would have taken less than 10 minutes. Very simple repair and it works like a charm, no more water coming into the refrigerator and the ice cream is rock hard. Glad we didn't have to spend lots on a new appliance. Thanks Part Select.com! BH
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Marion, IN
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
fan motor did not run all the time
unpluged refrigerator. removed panel in front of fan. Removed the fan motor. Installed the new fan kit. Replaced the panel in front of fan. Pluged the refrigerator back in. The refrigerator runs a 100 percent better
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Jefferson Township, PA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No Light
Took socket out and replace it with new one. Very easy. W saved alot of money doing it ourself.
Was this instruction helpful to you?
Thank you for voting!