Models > 2539239783 > Instructions

2539239783 Kenmore Freezer - Instructions

Jump to:

All Instructions for the 2539239783
61 - 71 of 71
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from GAINESVILLE, GA
Parts Used:
297013500
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replaced drawer slides L & R
Removed three screws each side to remove old slides. Needed spacers under new slide so that drawer would stay on track. Cut old slide to make spacers and installed both slides in 15 mins.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Yulee, FL
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Marshall, NC
Parts Used:
5303917954
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
freezer cold, fridge not cold
Removed shelving, and rear panels. Replaced condenser fan and defrost thermostat. Defrost coil ohmed fine. Reassembled and plugged in fridge with thermometers inside. Freezer at 22degrees and fridge at 32 degrees. My first time repairing a fridge. the partselect videos were very helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Macomb, MI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 2539239783
61 - 71 of 71