Donald from Lauderhill, FL
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Door would drop down when opened
Removed the door by removing the top hinge and lifting it off the broken bottom hinge/cam assembly. Removed the broken hinge/cam assembly found out why the cam broke the doorstop was bent so I had to order the doorstop also. The ordering of the parts was so easy. They shipped them on Monday and they arrived the next day. I will use Parts Select again
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Traci from Erie, PA
Parts Used:
WR2X7491, WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench set
Door would not close all of the way
I don't know exact details. My husband replaced parts while I held the door.

We removed connections for the door on the bottom (propped up on books). We installed the new cam, the old one cracked and broke, and the new shim and the door is now even with the top of the fridge. It was not before, and the seal near the bottom of the fridge was not solid. Now it is. It was very easy.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Max from TUCSON, AZ
Parts Used:
WR13X10020
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
lower door hinge worn
I replaced both lower hinges without removing the doors. First a couple of observations. The hinge kit consists of two parts; the lower part (bolted to the case) consists of an “L” bracket with a plastic cam, and the upper plastic cam (attached to the door). For some reason the upper cam is available as a separate part . If both cams are plastic both are worn out. Don’t bother ordering the individual cam. If one hinge is worn out the other probably isn’t far behind. Consider replacing both at the same time. Examine the door check. It is an inverted “T” shaped bracket bolted to the door that also holds the door cam. The crossbar of the T are metal tabs that check the door swing. Way too fragile IMO. On mine the refrigerator side was cracked and broke off when I removed it. Since the stops are the same right and left. I just swapped them when I replaced the hinges. Saved $22. Replacing the hinges without removing the doors. {Warning if this technique goes wrong you will be stuck with a loaded door you can’t open.} Remove the vent grill. Stack three 2x4’s along the bottom of both doors ( 26” is about right ). Shim the door(s) up to compensate for the cam wear. About 1/8”) Use a 5/16 socket to remove the hinge from the case. Pay attention to placement of the shims and spacers. Then remove the door cam and stop bracket. Install the new door cam. Leave the screws a little loose. Replace the lower hinge and tighten the screws. Do both sides. Then carefully remove the shims and 2x4’s. Finish tightening the door hinge screws. Check the door swing. I used this technique twice. One to replace the refrigerator side hinge, then again to replace the freezer side hinge and swap the door checks. There were no problems and I saved the hassle of unloading and removing the doors.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
T from SOUTHBURY, CT
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Original evaporator fan (31 years old) was making a lot of worn bearing noise
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.

I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.

Overall, this was an easy replacement.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from WILLIAMSBURG, VA
Parts Used:
WR2X4537
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Door would swing open too far and hit cabinets
The stop was bent and no longer stopped the door. However, by being bent, it interfered with removing one of the two hex head screws that held the stop in place. After taking pliers to break the bent portion off, the screws were easily removed with an 8 mm hex head ratchet wrench. Once the damaged (bent) stop was removed, the replacement was simple.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from CENTRALIA, IL
Parts Used:
WR23X37285, WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
light kept blinking on and off never same way
turn breaker off first then use thin blade screwdriver and plastic pry bar to remove light socket and switch there was plenty of wire so work was easy to install at both ends
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from BRANDON, MS
Parts Used:
WR13X10020
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Socket set
door hinge
put block of wood under the door, removed old hinge and installed the new one. about 15 minutes
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from WINTERVILLE, GA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
6 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marnie from Denver, CO
Parts Used:
WR60X114
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
a fan blade broken causing it to make a loud noise
we took off the old one and replaced it.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paypal_shipping_address from Ripon, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jodi from Benton Harbor, MI
Parts Used:
WR23X37285
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marc from Hollywood, FL
Parts Used:
WR71X2373
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Needed a new door module
Fit perfectly, took 2 seconds to install.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Statesboro, GA
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Refrigerator was not cooling
The refrigerator was no longer cooling and it was suggested by my father that it could be our defrost timer as he has owned many Hotpoint refrigerators in his lifetime and he said the defrost timer was always the problem he had with them when they were not cooling properly. I removed the cover and unplugged the defrost timer, ordered a new timer through this website and installed it by plugging it where the old timer was, replaced the cover and plugged the refrigerator back in. The refrigerator is now cooling again and just in time for Christmas.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Barnwell, SC
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refrig & Freezer Warmer than normal but could manually reset and defrost. Then good for several days.
Removed guard at bottomof frig. Located timer & performed tests. Manually rotated timer motor until defrost cycle start. Watched timer for several hours. Timer did not come out of defrost.. Rotated timer more until compressor started. Cooled fine several days then started to get warm again. Manually defrosted and started compressor again. Ordered part. Followed wiring diagram on timer for push on lugs. Frig now back to normal operation.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Santa Clarita, CA
Parts Used:
WR72X209, WR72X208, WR72X207, WR72X206
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
slide rails had broken on side by side
remove the 8 screws 2 for each rail
installed the new rails
slid in the meat drawer and glass
slid in the vegetable drawer and glass
presto - like new fridge !
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!