compressor stopped running
un plugged controller from compressor found controller burnt ohmed out compressor checked good ordered controller installed new controller plugged in freezer working ok now
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rob from HILLSBORO, NH
- Parts Used:
- 297243800
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
I knockedoff the door light sensor when I dropped a frozen jug of ice
I removed the plate (recommend using a magnetic phillips head screw driver to remmove screws which are recessed). I removed the old part and pushed the new part through the hole and carefully reached in behindto attach the wires to the new part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from ROSTRAVER TWP, PA
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from ARANSAS PASS, TX
- Parts Used:
- 5308000010
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- marilyn from Dunlap, TN
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Freezer would not stop running and had frosted over
Pretty simple, take cover off back of freezer to access thermostat, unhook thermostat and replace with new one. It had wire hookups different from original part so had to look up that information. Turned out it did not matter which wire went on which prong.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stirling from FORT WORTH, TX
- Parts Used:
- 5304518034
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marc from Chesterfield, MA
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer fine, fridge too hot!
Removed the back panel in freezer compartment with the nut-driver. Then I cut off old thermostat connections, and spliced in new thermostat connections (repairman had already replaced defrost timer, and said not to trust connectors included on wires-they failed often). Then I snapped thermostat itself onto cooler coil. So far so good, fridge is running at 35-40 degrees a week later. Thanks Parts-Select!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Tehachapi, CA
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Cooling coils would ice up and fridge would warm up
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.
Works great!!!
Works great!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Todd from Kewaskum, WI
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
My Freezer Was Frosting Up, My Ice Maker Was Not Working ,And My Fridge Was Warm.
Had to remove all screws on rear back cover of freezer inside, unplugged refridgerator, uncliped thermostat, unpluged thermostat. Replaced thermostat with new one in the same location, and let defrost fulley. Reassembled, pluged in, and tested. All was good. But I did also replace timer at first part of the repair so I suggest you replace both at the same time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Bowie, MD
- Parts Used:
- 297013500
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Brackets for the food basket were broken and the basket alwaws fell off the track.
Removed the basket. Removed the two broken brackets (6 screws). Installed the two new brackets. Put the basket on the track. Done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from Stockbridge, MI
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer frozen, refrigerator warm
removed the screws/nuts; pulled the back panel off, removed the old thermostat (wires just popped apart) replaced the new thermostat (wires just popped back on) replaced the back panel and the nuts and TaDa!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scot from Springfield, TN
- Parts Used:
- 216087400
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door handle caps cracked
It took just a few minutes after getting the parts to replace the cracked door handle caps - they fit perfectly!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- HAROLD from DETROIT, MI
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
REFRIDGERATOR SECTION WANST GETTING COLD
freezer section remove ice trays ,shelves,unplug ice tray.use 1/4 nut driver remove back panel,use hair dryer thaw ice from evap coil ,unplug tstat remove install new one.plug in ice maker,put back panel back on ,ice maker and shelves plug refridgerator back in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Toni from Little Rock, AR
- Parts Used:
- 297147700
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Just lost key
No repair. The key fit!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marsha from BEVERLY, MA
- Parts Used:
- 5304518034
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Refigerator Not Staying Cold
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Was this instruction helpful to you?
Thank you for voting!