Customer:
Edmond from Carroll, NH
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clovis, NM
Parts Used:
297309000, 5308000010
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CRAIG from PRESCOTT VALLEY, AZ
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Satellite Beach, FL
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shawnda from Union City, PA
Parts Used:
297216600, 5304464438
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
freezer not cooling
inspected visible refrigeration lines for evidence of leaking, found nothing substantial that would cause concern, ordered capacitor and defrost thermostat simply because both are inexpensive parts and theoretically either could be causing the problem. Both parts were very simple to install especially since I am a semi-retired refrigeration man.