Customer:
CRAIG from PRESCOTT VALLEY, AZ
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Gilroy, CA
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louis from Leander, TX
Parts Used:
297309000, 297147700
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Evaporator Fan Motor Noise
The evaporator fan would make a very high-pitched whine/squealing noise usually after starting up after a defrost cycle, although, it would make the same noises during normal operation. After performing a thorough inspection of the fan blade and motor, I discovered that there was no interference to the rotating fan, and realized the motor must be failing. After removing the food and racks from the main body of the freezer, I had to remove 8 Philips-tipped screws that held the inside back panel cover on. I disconnected the fan motor from the main wiring harness, removed the fan mounting bracket (2 5/16" hex head screws), and then removed the fan motor from the mounting bracket (2 5/16" hex head bolts. I removed the fan blade and conducted a visual inspection, and found not blemishes of broken/damaged pieces. I mounted the new motor and used the existing fan blade, and replaced everything in the reverse order. I turned on the freezer and it has been operating perfectly since. I disassembled the old motor and discovered that the stator coils were worn, and the bearings allowed to much forward/aft motion.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Macomb, MI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.