Customer:
Theodore from Vancouver, WA
Parts Used:
297311201
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The handle broke off at the bottom
I removed the top and bottom plastic bits that hide the screws. Then I removed the screws and put the new handle on with the same sheet-metal screws. No problems encountered.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rex from BEDFORD, WY
Parts Used:
5304513033
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Freezer would only run sometimes by turning the thermostat to highest position fully clockwise. Sometimes turning it full CW wouldn't turn on. Once the freezer would run on highest setting, it seemed that it wouldn't shut off. I put a thermometer inside and would read -15deg when running. +15-20deg.
Replaced thermostat and it fixed the problem. Freezer comes on and turns off automatically and regulates internal temperature around 2-5 degrees.
The hardest part was extending the coiled probe tubing and forming it to fit into clamp without kinking it.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DAVE from LOS RANCHOS, NM
Parts Used:
5304518034
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Defrost Timer
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. The video that was on-line helpful also.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Warren, MA
Parts Used:
5304507200
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
frost and ice build up/ gasket wasnt sealing properly
I did watch a repair a utube video which I asked for when ordering. Pretty much followed most of the directions but:

started in left corner an lossed all screws from left to right. took off old gasket in small sections and inserted the new gasket and semi tighten screws

proceeded down left side then right little by little as above. to get to bottom of door.

bottom corners were a little snug to get them into place. the last corner was snug but once connected. tighten screws not too tight. You dont want to strip them.

test door with piece of paper.

if paper is not a snug tug, you can adjust gasket with a hair dryer set to low.

it was easy. freezer is all set.

Partselect was great to deal with, support verified the part number was correct for my freezer and help with that video.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Jacksonville, FL
Parts Used:
297217900, 5303305677
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Copper lines leaking freon
Removed the inside evaporator coil to do inside solder job, use torch to heat solder joints on the outside drier in order to remove it and install new drier. Soldered Heat exchanger line to drier and 1/4” copper line to compressor. Wrapped with new insulation wrap. Pulled a vacuum on system and then charged with 4.4 ounces of 134a freon. Works like a champ again!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from DUNBAR, WV
Parts Used:
297147700
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Missing key
After removing the key from its shipping package I pushed it into the freezer locking slot and turned it to lock and unlock the lid and then removed it. I had no problems with this fix. Of course, I am an older gentleman with a lot of experience in repairs around my house,as well as other houses. I am sure that a less experienced person may have more of problem with this type of "repair".
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mel from LAKE CHARLES, LA
Parts Used:
5304496284
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Defroster and thermostat
Unplug freezer.
Open freezer and Remove the bottom 2 shelves and drawers.
Remove 6 screws (Phillips) securing the inside access panel located in the back of the unit.
Locate the defroster bar which is secured to the bottom of the condenser radiator. Trace the cable to the thermostat that is clipped into the condenser coil.
Unplug thermostat power cable located at the top left of the condenser coil, and the defroster bar cable on the upper right.
Release metal band that secures bar to the coil at the bottom where the coil and bar are secured.
Reverse for installation.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Roseburg, OR
Parts Used:
297283900
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Needed a left hand hinge
The left swing hinge (297283901) that i needed is not available anywhere so I bought the right swing hinge (297283900), used a hydraulic press to pop out the pin and move it to the other hole. After that it was real quick to remove the screws and change out the hinge, changing the swing of the door. It is easiest to remove the top hinge and door first when doing this.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from GRANBURY, TX
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dylan from Celina, OH
Parts Used:
297311201
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
handle broke at the attachment point on the door
removed two pieces of trim.....removed four screws of old handle.....replaced with new handle....replaced screws.....replaced trim pieces
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mervin from BOYD, TX
Parts Used:
5304513033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
It wouldn't restart when it turned off
I changed the cooling control
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from ROSTRAVER TWP, PA
Parts Used:
5304513033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
SALLY from DICKINSON, TX
Parts Used:
297311201
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
door handle broken at screws
removed 4 screws-replaced handle-very easy-worked great
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
marilyn from Dunlap, TN
Parts Used:
5304513033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Freezer would not stop running and had frosted over
Pretty simple, take cover off back of freezer to access thermostat, unhook thermostat and replace with new one. It had wire hookups different from original part so had to look up that information. Turned out it did not matter which wire went on which prong.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CONSTANCE from NEW COLUMBIA, PA
Parts Used:
5304507200
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Door alarm going off indicating door ajar
This did not fix the problem. Call a repairman and he cannot come until 9/11. Food is staying frozen. Alarm sounds for awhile and then shuts off for a bit.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FFUH17F2NWA