- Customer:
- Tunis from NOLANVILLE, TX
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rex from BEDFORD, WY
- Parts Used:
- 5304513033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Freezer would only run sometimes by turning the thermostat to highest position fully clockwise. Sometimes turning it full CW wouldn't turn on. Once the freezer would run on highest setting, it seemed that it wouldn't shut off. I put a thermometer inside and would read -15deg when running. +15-20deg.
Replaced thermostat and it fixed the problem. Freezer comes on and turns off automatically and regulates internal temperature around 2-5 degrees.
The hardest part was extending the coiled probe tubing and forming it to fit into clamp without kinking it.
The hardest part was extending the coiled probe tubing and forming it to fit into clamp without kinking it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from SLIDELL, LA
- Parts Used:
- 297216600
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leah from Tecumseh, OK
- Parts Used:
- 242252603
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
After installing new ice maker water was not running into the ice maker.
Shut off water supply under the sink. Removed old valve and installed new valve. Turned water back on and within a couple hours the first batch of ice made.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Danny from PUEBLO, CO
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Drive great stripped for ice eject. Heater bad
Loosened the 2 bolts 4 turns where it mounts inside the freezer. Lift maker off the bolts unplug 1 plug. Reverse to install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- wissam farhat from medley, FL
- Parts Used:
- 216514000
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
End cap for side door shelf broken
Both end caps were missing on the door side bottom metal shelf. succesfully installed no tools needed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Lockport, NY
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from KNOXVILLE, TN
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker would dump ice one time and then stop. Turning the ice maker off for a minute and back on would repeat the process.
I removed the two side mount screws with a screwdriver and disconnected the electrical plug to the ice maker to remove it. I reversed the process to install the new one.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from GROTON, CT
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working. Part needed to repair it no longer available so had to replace the whole icemaker.
Loosened the two mounting screws (no need to remove them), lift off the icemaker and unplug it. Reverse the order and done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Jacksonville, FL
- Parts Used:
- 297217900, 5303305677
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Copper lines leaking freon
Removed the inside evaporator coil to do inside solder job, use torch to heat solder joints on the outside drier in order to remove it and install new drier. Soldered Heat exchanger line to drier and 1/4” copper line to compressor. Wrapped with new insulation wrap. Pulled a vacuum on system and then charged with 4.4 ounces of 134a freon. Works like a champ again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from WALLING, TN
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from GULF SHORES, AL
- Parts Used:
- 297237702
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Not a original factory direct replacement part
The housing is not the same where the wires attach. I had to cut off the plastic shroud around barbs on start relay to accept the original larger wire end Fittings.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from ROSTRAVER TWP, PA
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from PRAIRIEVILLE, LA
- Parts Used:
- 5304518034, 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andy from GOOSE CREEK, SC
- Parts Used:
- 218909912
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Was this instruction helpful to you?
Thank you for voting!