Models > LFFU1766GW4 > Instructions

LFFU1766GW4 Frigidaire Freezer - Instructions

Jump to:

All Instructions for the LFFU1766GW4
91 - 105 of 116
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Kevin from Frisco, TX
Parts Used:
297216600, 5304513033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer not staying cold enough
After researching other issues found on internet about same problem, decided to replace both thermostat and temperature control thermastat before going to the repairman way. I saw the videos given on this web site, ordered the parts and when they came in, unplugged freezer and started taking apart the back cover not sure what I would find. Turns out it was just that simple, unplugged the thermastat and unclipped it from the cooling fins, unplugged the temperature control switch and then plugged both units back in. The tricky part was coiling the temperature sensor ( not that tricky). I was done in about 45 minutes but that also included cleaning out and scrubbing the bottom and sides of freezer since I had everything out anyways. Started the freezer back up and took about 8 hours to freeze ice and other food at a setting of 4, where as before I had it set on 7 and was still not keeping the ice cream cold.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Front Royal, VA
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer freezes up; lower unit to warm
Replaced freezer defrost thermostat. Unit worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clovis, NM
Parts Used:
297309000, 5308000010
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edmond from Carroll, NH
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Yulee, FL
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the LFFU1766GW4