FCFS201LFB3 Frigidaire Freezer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Nick from Silver Spring, MD
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
would not defrost
Replace thermostat and show and tell made it easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from San Marcos, TX
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer would constantly run. Even when it was super cold inside.
I ordered a new thermostat and installed it in less than 15 minutes. Looks like the problem is fixed. Now ,the freezer cycles on and off correctly. The part was ordered on a Monday and I got it the next day. I am very satisfied.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Gilroy, CA
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RONALD from Sevierville, TN
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ricardo from VICTORVILLE, CA
- Parts Used:
- 297243800
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
door switch broke
Removed bottom cover , just two screws , slid old part through install hole and removed wires from old switch and installed on new switch. Installed new switch in same hole and pushed gently until it locked in place. Reinstalled bottom cover and done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from royal oaks, CA
- Parts Used:
- 5304518034, 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
coils would freeze over not allowing air to circulate throughout freezer
replace thermostat and timer after defrosting and cleaning out freezer. I took less than 10 minutes and now freezer has a defrost cycle that eliminates frost buildup on the coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Satellite Beach, FL
- Parts Used:
- 297309000
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Was this instruction helpful to you?
Thank you for voting!