freezer not maintining adequate temperature
replaced controller start capacitor as per troubleshooting checklist. Was not the problem, then replace controller kit. seems to have resolved the problem.Temperature more constant. The problem with this refrig though in my opinion is that only one thermostat controls both the freezer compartment evap fan in freezercompartment also blows cold air into refrigcomp. There is not very much control over both temps. Am in monitoring both compartments and hoping that freezer will keep things frozen
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Winlock, WA
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
won't start repaced the run capacitor didn't solve the problem so I ordered a defrost timer
I watched the videos (they really help) and followed the steps. Everything went smooth with no surprises
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- FRANK from BRADENTON, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Frige and freezer not cooling
I should have ordered start kit instead of start capacitor. The start cap astir did not fix problem so I ordered kit. Compasator comes as part of kit. Followed enclosed instructions. Cut existing wires and reconnected new wiring. Simple as that. It's a plug in item. Now worried it may be working to good. Freezer down to 10 deg. Watching to see if compressor is running to long. Seems ok lol. Wife hates me now. She wanted new frige.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Fresno, CA
- Parts Used:
- 297147700
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
freezer door got locked and we couldn't find the key
inserted key and turned
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from royal oaks, CA
- Parts Used:
- 5304518034, 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
coils would freeze over not allowing air to circulate throughout freezer
replace thermostat and timer after defrosting and cleaning out freezer. I took less than 10 minutes and now freezer has a defrost cycle that eliminates frost buildup on the coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bart from goldsboro, NC
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the compressor capacitor overheated
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- wilson from indialantic, FL
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
compressor not running
thanks to all of the people who had the same problems I was able to make a quick fix on my fridge. I pulled the back cover off and found the compressor not kicking on so I replaced the start cap. and im back in bussiness.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Satellite Beach, FL
- Parts Used:
- 297309000
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shawnda from Union City, PA
- Parts Used:
- 297216600, 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
freezer not cooling
inspected visible refrigeration lines for evidence of leaking, found nothing substantial that would cause concern, ordered capacitor and defrost thermostat simply because both are inexpensive parts and theoretically either could be causing the problem. Both parts were very simple to install especially since I am a semi-retired refrigeration man.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nick from Silver Spring, MD
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
would not defrost
Replace thermostat and show and tell made it easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RONALD from Sevierville, TN
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philippa from New York, NY
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer was no longer keeping items frozen,
I followed the You-Tube instructions, removed the ice from the compressor and replaced the thermostat with the part I received from Part Select. What I took out was a part that was very much inferior to the replacement part. The repair saved me a lot of money for a new freezer and it was not difficult to do following the video. Now the freezer runs better and quieter than ever. Thank you Parts Select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Chatham, IL
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Temp skyrocketed
Took out three shelves. Removed 9 screws with a battery powered drill with a phillip screwdriver bit. Popped off the thermostat like I had seen on the video. Put the new thermostat on. Replaced the two wires one at a time. Reassembled the unit. This was so quick that my wife told me to let her know when I wanted to fix the freezer. She was shocked that I had completed the job. I'd been in the garage less than 10 minutes. It has been six weeks. and the freezer is working perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CRAIG from PRESCOTT VALLEY, AZ
- Parts Used:
- 297309000
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Was this instruction helpful to you?
Thank you for voting!
Freezer only cold on bottom
Pulled freezer out from where located to allow shelves to be removed.Unplugged unit, removed shelves and evaporator cover, installed new fan motor. Plugged unit up to check fan motor operation. Reassembled unit, installed shelves and moved freezer back into original location.
Was this instruction helpful to you?
Thank you for voting!