George from McBee, SC
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from SUNDANCE, WY
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
fan motor quit working
A little difficult getting out due to restricted space, I took off the fan blade, that gave extra working room. Then it went well going back together,and it all worked as advertised. Thanks. p
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from WHITEHALL, NY
Parts Used:
240524102
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broken fan blade
I remove the old fan by pushing it off the spindle toward the evaporator and put the new one on by holding it on the right side and guiding it on the spindle from the left side, very easy task
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from SLIDELL, LA
Parts Used:
297216600
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
wissam farhat from medley, FL
Parts Used:
216514000
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
End cap for side door shelf broken
Both end caps were missing on the door side bottom metal shelf. succesfully installed no tools needed
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol from Lawrence, KS
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Piece broken off of drawer slide
I removed the screws and replace the broken slide with the new slide. Put the basket drawer back on the track and it now stays in place and can easily be used once again.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tunis from NOLANVILLE, TX
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mervin from BOYD, TX
Parts Used:
5304513033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
It wouldn't restart when it turned off
I changed the cooling control
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from ST PETERSBURG, FL
Parts Used:
240524102
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
fan blade broke
Received fan blade part took about 5 min to install and running great.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from PRAIRIEVILLE, LA
Parts Used:
5304518034, 297216600
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from GRANBURY, TX
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
warren from Farmdale, OH
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken drawer slide
removed old broken part, 3 screws, then installed new part.....done
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from STERLING, VA
Parts Used:
5303918774
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Condenser motor burned out
I followed the instructions on your website, made it a simple as possible. Very tight work area sometimes fingers only, but a little patience works.
Saved at least $300. By not paying a repair person.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
marilyn from Dunlap, TN
Parts Used:
5304513033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Freezer would not stop running and had frosted over
Pretty simple, take cover off back of freezer to access thermostat, unhook thermostat and replace with new one. It had wire hookups different from original part so had to look up that information. Turned out it did not matter which wire went on which prong.
2 of 2 people found this instruction helpful.