Tom from Argyle, WI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Elvin from Gardner, KS
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffry from VERONA, WI
Parts Used:
5304518034, 297216600
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
The freezer was not keeping food frozen
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.

Compared to the training video, the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from SAN ANTONIO, TX
Parts Used:
5304518034
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matt from Cincinnati, OH
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer was freezing solid
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
VICKIE from DAWSON, GA
Parts Used:
297147700
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
I Lost The Key
I order another one thanks
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from SEYMOUR, TN
Parts Used:
5304496687
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Compressor keep running would not cool.frozen coil
As per instructions.removed inside shelves.removed back cover over coil let thaw.removed old thermostat &clips as per instructions.replaced with new.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tunis from NOLANVILLE, TX
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from SLIDELL, LA
Parts Used:
297216600
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from DUNBAR, WV
Parts Used:
297147700
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Missing key
After removing the key from its shipping package I pushed it into the freezer locking slot and turned it to lock and unlock the lid and then removed it. I had no problems with this fix. Of course, I am an older gentleman with a lot of experience in repairs around my house,as well as other houses. I am sure that a less experienced person may have more of problem with this type of "repair".
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from GRANBURY, TX
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from PRAIRIEVILLE, LA
Parts Used:
5304518034, 297216600
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gene from VICTORVILLE, CA
Parts Used:
5304507201
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Getting frost build up on the inside at the top of the door .
removed door and took all the screws out of the inside door rack. removed old door seal . replaced door seal and made sure that the seal fit around and door rack fit into the groove then replaced all screws and tightened choosing random sections to tighten .replaced the door plugged back in wires that I removed and replaced door hinge screws . Shut door and checked sealing 2 hours later .Complete seal .
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stirling from FORT WORTH, TX
Parts Used:
5304518034
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
2 of 3 people found this instruction helpful.