Freezer would not run; no electrical power to the compressor
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web site that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert H. from Grand Blanc, MI
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Rafael, CA
- Parts Used:
- 297147700
- Difficulty Level:
- Difficult
- Total Repair Time:
- Less than 15 mins
Lost Locked Freezer Door Key
Had to drag the full freezer out from the wall to expose the name plate, got the Model # and S/N and found the key on the partselect website in minutes. It was cheap so I got two. Other than FEDEX not knowing my address correctly, when I finally got the key it worked fine. Not a problem anymore.
Thanks
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rex from Ritzville, WA
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer had stopped cooling for almost 30hours.
Turned thermostat down and freezer began to run. Once it was at desired temp it shut down and did not start again. Turning the thermostat down again caused the freezer to start again. At this point, decided the thermostat was defective.Unplugged the freezer and removed the shelving. Removed the knob from the thermostat. Removed the nine screws that held the back panel in place and pulled the panel forward. Removed the assembly that held the sensing tube in place and removed the sensing tube from it. Depressed the thermostat latch which holds it in the back panel and separated it from the panel. Removed the electrical connections and removed the thermostat assembly from the freezer. Reinstalled the new thermostat in the reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Indianapolis, IN
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker was not making ice
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from SOUTH LYON, MI
- Parts Used:
- 241798231
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker failed
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JEFF from COLONIAL BEACH, VA
- Parts Used:
- 297051000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
freezer stopped freezing but would attempt to start
After Sear told me it would cost $289 to repair my $350 freezer. (They charged me $65 to tell me this)
I went on line and found you guys. Found a part diagram. Looked for the weakest link. Then pulled my freezer away from the wall, got down and found the same part I suspected was the weakest link (attached to compressor) pulled it off shook it and it rattled, being plastic and cheap looking I figured I found the problem) Paid 28+ for it, it arrived, I installed and I'm freezing up a storm and a hero.
jeff kern
deputy sheriff
I went on line and found you guys. Found a part diagram. Looked for the weakest link. Then pulled my freezer away from the wall, got down and found the same part I suspected was the weakest link (attached to compressor) pulled it off shook it and it rattled, being plastic and cheap looking I figured I found the problem) Paid 28+ for it, it arrived, I installed and I'm freezing up a storm and a hero.
jeff kern
deputy sheriff
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Los Banos, CA
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard Allen from PHOENIX, AZ
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Replacing Icemaker
Pull refrigerator from wall and disconnect the water line and unplug the power.
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Danielle from LAKEWOOD, CO
- Parts Used:
- 297147700
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Freezer Door Leaking
My issue was water leaking from the door. I thought it was the gasket, so I removed the gasket and the entire panel off of the door. There was water behind it that had soaked the cardboard seal, so I left that front part off for over a week to let it dry. We determined between us and our two toddlers that perhaps the door hadn't been properly closed enough on a number of occasions, so before I bought a $100 gasket, I'd try making sure the door was shut with tape, turning the freezer on and seeing what happened. There was no water after a few days, so on another user's suggestion I purchased the $15 key and twist tied it to the freezer door. Now I am locking the door after use so we won't have leaking water any longer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from Las Vegas, NV
- Parts Used:
- 242252603
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working
Took off old part and installed new part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Argyle, WI
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Elvin from Gardner, KS
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barry from Middletown, DE
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
ice maker quit making ice
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Azle, TX
- Parts Used:
- 5303918277
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Original Ice Maker quit working.
Loosened the 2 screws a little so that it would slide up and off then unplugged the wire harness.
Installed the new one in reverse order and works like a champ.
Installed the new one in reverse order and works like a champ.
Was this instruction helpful to you?
Thank you for voting!