Joseph from Yulee, FL
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Hudson, FL
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
not cold enough
per the video..easy installation....unfortunately the temperature did not improve. We still have a refrigerator temp in the upper freezer.....and a "cooler" in the refrigerator section
Was this instruction helpful to you?
Thank you for voting!
Customer:
FRANK from BRADENTON, FL
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Frige and freezer not cooling
I should have ordered start kit instead of start capacitor. The start cap astir did not fix problem so I ordered kit. Compasator comes as part of kit. Followed enclosed instructions. Cut existing wires and reconnected new wiring. Simple as that. It's a plug in item. Now worried it may be working to good. Freezer down to 10 deg. Watching to see if compressor is running to long. Seems ok lol. Wife hates me now. She wanted new frige.