LFFH1767DW0 Frigidaire Freezer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Joseph from BANDON, OR
- Parts Used:
- 5304518034, 5304491584, 297216600, 218909912
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Compressor stopped running, freezer stopped freezing
Upon Inspection of electrical connections I found the controller connector slightly melted, so I ordered a replacement and the other parts, given the freeezers age.
Replacement efforts were close to plug and play.
Compressor powered back up And freezer is now functioning again.
Replacement efforts were close to plug and play.
Compressor powered back up And freezer is now functioning again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from GRANBURY, TX
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andy from GOOSE CREEK, SC
- Parts Used:
- 218909912
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CONSTANCE from NEW COLUMBIA, PA
- Parts Used:
- 5304507200
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Door alarm going off indicating door ajar
This did not fix the problem. Call a repairman and he cannot come until 9/11. Food is staying frozen. Alarm sounds for awhile and then shuts off for a bit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yvonne from CORP CHRISTI, TX
- Parts Used:
- 297309000, 5305878546
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fan motor died.
Remove shelves. Unplug unit. Unscrew back panel. Remove wire harness. Remove old fan. Insert new fan. Screw it in. Reattach wires harness. Plug unit in and make sure fan is on.
Reattach back panel. Put shelves back in.
Reattach back panel. Put shelves back in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- warren from Farmdale, OH
- Parts Used:
- 297013500
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken drawer slide
removed old broken part, 3 screws, then installed new part.....done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from PRAIRIEVILLE, LA
- Parts Used:
- 5304518034, 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- marilyn from Dunlap, TN
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Freezer would not stop running and had frosted over
Pretty simple, take cover off back of freezer to access thermostat, unhook thermostat and replace with new one. It had wire hookups different from original part so had to look up that information. Turned out it did not matter which wire went on which prong.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mervin from BOYD, TX
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
It wouldn't restart when it turned off
I changed the cooling control
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from ROSTRAVER TWP, PA
- Parts Used:
- 5304513033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Tehachapi, CA
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Cooling coils would ice up and fridge would warm up
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.
Works great!!!
Works great!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from Stockbridge, MI
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer frozen, refrigerator warm
removed the screws/nuts; pulled the back panel off, removed the old thermostat (wires just popped apart) replaced the new thermostat (wires just popped back on) replaced the back panel and the nuts and TaDa!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Xavier from Philadelphia, PA
- Parts Used:
- 297216600
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The freezer was too warm. The fan was running: the diagnosis tool did not work!
I used the tool at Partselect that in theory allows diagnostic of the problem to be repaired. The result was that more tan 90% of the time with the introduced symptoms it had to be the thermostat. I order the part, got it quickly and installed. It did not fix the problem. So, be careful with the diagnostic tool, because it is just based on what most people buy when they have a particular problem. Videos for installation are great. If diagnosis was better, this would be fantastic. In my case there might be a different problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marc from Chesterfield, MA
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer fine, fridge too hot!
Removed the back panel in freezer compartment with the nut-driver. Then I cut off old thermostat connections, and spliced in new thermostat connections (repairman had already replaced defrost timer, and said not to trust connectors included on wires-they failed often). Then I snapped thermostat itself onto cooler coil. So far so good, fridge is running at 35-40 degrees a week later. Thanks Parts-Select!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Todd from Kewaskum, WI
- Parts Used:
- 297216600
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
My Freezer Was Frosting Up, My Ice Maker Was Not Working ,And My Fridge Was Warm.
Had to remove all screws on rear back cover of freezer inside, unplugged refridgerator, uncliped thermostat, unpluged thermostat. Replaced thermostat with new one in the same location, and let defrost fulley. Reassembled, pluged in, and tested. All was good. But I did also replace timer at first part of the repair so I suggest you replace both at the same time.
Was this instruction helpful to you?
Thank you for voting!